ELTEC CABLES AND INSTRUMENTS
None

Call us:

trusted seller

RTD Cable

RTD Cable are the conductive elements that are especially designed for the resistance thermometers for the measurement of temperatures. These wires are manufactured by sing premium quality materials such as copper, nickel and titanium which offers very less resistance for the smoother transmission of the current signals. RTD Cable availed by us are available in multi wired designs provided with insulated coating to prevent short circuit. These this conductive elements are used to send or receive signals from the RTD sensors. Buyers can get these premium grade electrical elements from us in bulk in various different lengths in between 100 to 500 metres.

ELTEC RTD Cables

ELTEC RTD Cables are designed to meet the highest industrial standards. They are made from high-quality ELTEC material and feature a fiber insulation material for maximum safety and reliability. Available in four sizes (24*7*32 / 26*7*34 / 20*19*32 / 22*19*34) to meet a variety of client requirements, these cables come in a classic gray color. ELTEC RTD Cables are perfect for any industrial application and provide superior performance and reliability.

FAQ :

Q: What is ELTEC RTD Cables?
A: ELTEC RTD Cables are industrial cables made from ELTEC material and insulated with fiber. They come in several sizes, including 24*7*32, 26*7*34, 20*19*32, and 22*19*34, depending on the clients requirements. The cables are gray in color.

Q: What is the purpose of ELTEC RTD Cables?
A: ELTEC RTD Cables are designed for industrial applications. They are used to transmit data, signals, and power between different devices and systems.

Q: What are the advantages of using ELTEC RTD Cables?
A: ELTEC RTD Cables are strong and durable, and they provide reliable performance. They are also insulated with fiber, which helps to protect against electrical interference.

Q: Are ELTEC RTD Cables available in different sizes?
A: Yes, ELTEC RTD Cables are available in several sizes, including 24*7*32, 26*7*34, 20*19*32, and 22*19*34, depending on the clients requirements.

Specification

Conductor Type

Silver Plated Copper / Nickel Plated Copper

Size

24*7*32 / 26*7*34 / 20*19*32 / 22*19*34 as per client's requirements

Material

PTFE / FEP / PFA / PVC

Product Type

RTD CABLES

Brand

ELTEC

Thermocouple Type

RTD

Number Of Core

As per client's requirements

Usage/Application

Use to transmit signals from RTD SENSORS to control unit

Operating Temp

-60 to 260 C

Power/Voltage

250V / 600V / 1000V

 

Technical Details 

Send Inquiry

ELTEC Ptfe Insulated Rtd Cable

The ELTEC Ptfe Insulated RTD Cable is a reliable, durable solution for any industrial application. This cable is constructed with a gray fiber insulation material and is available in sizes ranging from 28 AWG to 20 AWG. It is made with ELTEC material to ensure superior performance and reliability. The cable is designed to provide superior electrical insulation and temperature resistance, making it ideal for applications where temperature control is critical. Its flexibility and durability make it a great choice for any industrial application. With its superior insulation and temperature resistance, the ELTEC Ptfe Insulated RTD Cable is the perfect choice for any industrial application.

FAQ :

Q: What is ELTEC Ptfe Insulated Rtd Cable?
A: ELTEC Ptfe Insulated Rtd Cable is a type of cable that is insulated with a fiber material and has a size range of 28 AWG to 20 AWG. It is manufactured by ELTEC and is typically gray in color.

Q: What are the features of ELTEC Ptfe Insulated Rtd Cable?
A: ELTEC Ptfe Insulated Rtd Cable features a fiber insulation material, a size range of 28 AWG to 20 AWG, and is manufactured by ELTEC.

Q: What is the color of ELTEC Ptfe Insulated Rtd Cable?
A: ELTEC Ptfe Insulated Rtd Cable is typically gray in color.

Specification

Size

28 AWG to 20 AWG

Usage/Application

RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit.

Insulating Material

PTFE

Brand

ELTEC

Number Of Cores

2,3,4,6 or more

Conductor Material

Silver Plated Copper / Nickle Plated Copper wires

Country of Origin

Made in India

 

Technical Details 

ELTEC Silicon Rubber Insulated RTD CABLES

ELTEC Silicon Rubber Insulated RTD Cables are designed to offer reliable and durable performance in industrial applications. These cables are manufactured using high-grade ELTEC material and are available in white color. The cables feature multi stranded conductors ranging from 28 AWG to 20 AWG, ensuring superior conductivity and flexibility. They are designed to withstand extreme temperatures and harsh environmental conditions, making them ideal for industrial usage. These cables offer excellent resistance to abrasion, chemicals and moisture, making them a reliable and cost-effective solution for a wide range of industrial applications.

FAQ :

Q: What type of product is ELTEC Silicon Rubber Insulated RTD CABLES?
A: ELTEC Silicon Rubber Insulated RTD CABLES is a type of cable used for industrial applications.

Q: What material is ELTEC Silicon Rubber Insulated RTD CABLES made of?
A: ELTEC Silicon Rubber Insulated RTD CABLES is made of ELTEC material.

Q: What color is ELTEC Silicon Rubber Insulated RTD CABLES?
A: ELTEC Silicon Rubber Insulated RTD CABLES is white in color.

Q: What is the size of ELTEC Silicon Rubber Insulated RTD CABLES?
A: ELTEC Silicon Rubber Insulated RTD CABLES is available in sizes ranging from 28 AWG to 20 AWG Multi stranded conductors.

Q: What is the usage of ELTEC Silicon Rubber Insulated RTD CABLES?
A: ELTEC Silicon Rubber Insulated RTD CABLES is designed for industrial applications.

Specification

Country of Origin

Made in India

Conductor

Silver Plated / Nickel Plated Copper wires

Conductor size

28 AWG to 20 AWG Multi stranded conductors

Insulation

Silicone Rubber or PTFE as per user requirement

Sheath Material

Silicone Rubber

Color Code Specification

As per EN 60751

 

RTD WIRE PFA

RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8, 9  cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction.

ELTEC PTFE Insulated RTD Extension wires conforms to US Military MIL 16878 and Indian defense specifications JSS 51034.92. As per these standards, these wires are classified in three main working voltage grades.                                                                                          

HV TEST

GRADE

SPARK TESTING

DIE ELECTRIC TESTING

ET (250 V)

2500 V ACrms

1500 V ACrms

E (600 V)

3400 V ACrms

2000 V ACrms

EE (1000 V)

5000 V ACrms

3000 V ACrms


APPLICATIONS

PRODUCT FEATURES

          RTD Sensors & Extension Wires

       Continuous use up to 200 C

          RTD Autoclave

Smooth External surface finish

          Medical Instruments & Scientific Equipments

Flame Retardant

          Sensors, Load Cells & Pressure Transducers

 Excellent resistant to chemicals

          Electronics & Communication Equipment

 Excellent electrical properties

          Process Instrumentation

    Moisture Resistant

          Packaging

  Greater Flexibility

 

PRODUCT  SPECIFICTIONS:

Conductor

Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL 168780 & JSS 5103492, Refer Table for most popular & standard wire sizes.

Core Insulation

Flame Retardant extruded  PFA

No. of Cores

2, 4, 6, 8 or even more

Construction

Parallel Conductors

Outer Sheath

Flame Retardant extruded PFA

SS  JACKET

Optional Outside SS Metal braid

Color Coding

Confirms to EN 60751

 

Other sizes in SWG and also different construction in other stranded sizes are available on request

Optional construction of twisted conductors & shielding

Duplex construction are also available

Optional Color coding: IEC 605843, BS 1843, DIN 13711, JIS C 16101981, NFC 42334 as per   requirement

                                                          

 

RTD Extension Wire Rx TFS

RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8, 9  cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction.

ELTEC PTFE Insulated RTD Extension wires conforms to US Military MIL 16878 and Indian defense specifications JSS 51034.92. As per these standards, these wires are classified in three main working voltage grades.

HV TEST

GRADE

SPARK TESTING

DIE ELECTRIC TESTING

ET (250 V)

2500 V ACrms

1500 V ACrms

E (600 V)

3400 V ACrms

2000 V ACrms

EE (1000 V)

5000 V ACrms

3000 V ACrms


APPLICATIONS

PRODUCT FEATURES

          RTD Sensors & Extension Wires

          Continuous use up to 260 C

          RTD Autoclave

          Single exposure up to 650 C

          Medical Instruments & Scientific Equipments

          Good Thermal Durability & Strength

          Sensors, Load Cells & Pressure Transducers

          Flame Retardant

          Electronics & Communication Equipment

          Superior Abrasion Resistance

          Process Instrumentation

          Better flexibility

          Packaging

 


PRODUCT  SPECIFICTIONS:

Conductor

Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL 168780 & JSS 5103492, Refer Table for most popular & standard wire sizes.

Core Insulation

Parallel Conductors

No. of Cores

2, 4, 6, 8 or even more

Construction

Cores twisted

Outer Sheath

Braided Fiber Glass with high temperature impregnation*

SS  JACKET

Optional Outside SS Metal braid

Color Coding

Confirms to EN 60751

 

       Impregnation maintained up to 200 C. Option for supply of wire without impregnation for continuous operation at elevated temperature.       

          Optional construction of twisted conductors.

          Duplex construction are also availab    Optional Color coding: IEC 60584 1981, NFC 42334 as per requirement

 

RTD Extension Wire Rx TT

RTD Extension Wire Rx TT

 RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8,9  cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction.


 ELTEC PTFE Insulated RTD Extension wires conforms to US Military MIL  16878 and Indian defense specifications JSS 51034. As per these standards, these wires are classified in three main working voltage grades. 

HV TEST

           GRADE

SPARK TESTING

DIE ELECTRIC TESTING

ET (250 V)

2500 V AC

1500 V AC

E (600 V)

3400 V AC

2000 V AC

EE (1000 V)

5000 V AC

3000 V AC

 

APPLICATIONS

PRODUCT FEATURES

          RTD Sensors & Extension Wires

           Continuous use up to 260 C

          RTD Autoclave

          Single exposure up to 400 C

          Medical Instruments & Scientific Equipments

          Inert to most chemical & fluids

          Sensors, Load Cells & Pressure Transducers

          Unaffected by lubricants

          Electronics & Communication Equipment

          Flame Retardant

          Process Instrumentation

          Immune to agene fungus & water absorption

          Packaging

          Resistant to gamma radiation

 

PRODUCT  SPECIFICTIONS:

Conductor

Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL W - 16878 & JSS 51043, Refer Table for most popular & standard wire sizes.

Core Insulation

Fused PTFE tape

No. of Cores

2, 3, 4, 6, 8 or even more

Construction

Cores twisted

Outer Sheath

Fused PTFE  tape

Color Coding

Confirms to EN 60751

                Other sizes in SWG and also different construction in other stranded sizes are available on request

          Optional Nickel Plated Copper Conductors.    

                                                                                                                                                                                                                                                                     FEW POPULAR RTD CABLE WIRE SIZES as per MIL 16878 

Sr. No.

Size in AWG

No. of strands/dia. of each strand (mm)

Parameters of conductor (Nominal)
(As per JSS 51034)

Nominal Dia. of Insulated Wire

Dia. (mm)

Cross section (sq. mm)

Resistance Ohm/km at 20 C

Elongation % (Min)

ET
(250 V) AC

E
(600 V ) AC

EE
(1000 V) AC

 

1.

26/7/34

7/0.16

0.48

0.1409

133.7

9.0

0.79

0.99

1.24

 

2.

24/7/32

7/0.2

0.60

0.2270

83.2

9.0

0.91

1.12

1.37

 

3.

24/19/36

19/0.13

0.63

0.2407

80.2

9.0

0.91

1.12

1.37

 

4.

22/7/30

7/0.25

0.75

0.3547

52.5

13.5

1.07

1.27

1.52

 

5.

22/19/34

19/0.16

0.80

0.3820

49.8

9.0

1.07

1.27

1.52

 

6.

20/7/28

7/0.32

0.97

0.5630

33.0

13.5

1.27

1.47

1.73

 

7.

20/19/32

19/0.2

1.00

0.6162

30.3

9.0

1.27

1.47

1.73

 














 

 

RTD Extension Wire Rx TTS

RTD Extension Wire Rx TTS

 RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8,9  cores as per the  requirement of RTD SENSOR design for Simplex & Duplex Construction.

ELTEC PTFE Insulated RTD Extension wires conforms to US Military MIL 16878 and Indian defense specifications JSS 51034. As per these standards, these wires are classified in three main working voltage grades.

HV TEST       

GRADE

SPARK TESTING

DIE ELECTRIC TESTING

ET (250 V)

2500 V AC

1500 V AC

E (600 V)

3400 V AC

2000 V AC

EE (1000 V)

5000 V AC

3000 V AC


APPLICATIONS

PRODUCT FEATURES

          RTD Sensors & Extension Wires

          Continuous use up to 260 C

          RTD Autoclave

          Single exposure up to 400 C

          Medical Instruments & Scientific Equipments

          Inert to most chemical & fluids

          Sensors, Load Cells & Pressure Transducers

          Unaffected by lubricants

          Electronics & Communication Equipment

          Flame Retardant

          Process Instrumentation

          Immune to agene fungus & water absorption

          Packaging

          Resistant to gamma radiation


PRODUCT  SPECIFICTIONS:

Conductor

Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL  W - 16878 & JSS 51043, Refer Table for most popular & standard wire sizes.

Core Insulation

Fused PTFE tape

No. of Cores

2, 3, 4, 6, 8 or even more

Construction

Cores twisted

Outer Sheath

Fused PTFE tape

SS  JACKET

Outside SS METAL Over braid

Color Coding

Confirms to EN 60751

          Other sizes in SWG and also different construction in other stranded sizes are available on request

          Optional Nickel Plated Copper Conductors.

FEW POPULAR RTD CABLE WIRE SIZES as per MIL 16878

 

Sr. No.

Size in AWG

No. of strands/dia. of each strand (mm)

Parameters of conductor (Nominal)
(As per JSS 51034)

Nominal Dia. of Insulated Wire

Dia. (mm)

Cross section (sq. mm)

Resistance Ohm/km at   C

Elongation % (Min)

ET
(250 V) AC

E
(600 V ) AC

EE
(1000 V) AC

 

1.

26/7/34

7/0.16

0.48

0.1409

133.7

9.0

0.79

0.99

1.24

 

2.

24/7/32

7/0.2

0.60

0.2270

83.2

9.0

0.91

1.12

1.37

 

3.

24/19/36

19/0.13

0.63

0.2407

80.2

9.0

0.91

1.12

1.37

 

4.

22/7/30

7/0.25

0.75

0.3547

52.5

13.5

1.07

1.27

1.52

 

5.

22/19/34

19/0.16

0.80

0.3820

49.8

9.0

1.07

1.27

1.52

 

6.

20/7/28

7/0.32

0.97

0.5630

33.0

13.5

1.27

1.47

1.73

 

7.

20/19/32

19/0.2

1.00

0.6162

30.3

9.0

1.27

1.47

1.73

 


  

 

 

RTD Extension Wire Rx FFS

RTD Extension Wire Rx FFS

RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8,9  cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction. The main application of these wires is for extreme temperature conditions.

APPLICATIONS

PRODUCT FEATURES

          RTD Sensors & Extension Wires

        Continuous use up to 400 C

         RTD Autoclave

        Single exposure up to 500 C

        Medical Instruments & Scientific Equipments

        Good Thermal Durability & Strength

        Sensors, Load Cells & Pressure Transducers

        Flame Retardant

         Electronics & Communication Equipment       

        Superior Abrasion Resistance

        Process Instrumentation

        Better flexibility


PRODUCT  SPECIFICTIONS:

Conductor

Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL 168780 & JSS 5103492, Refer Table for most popular & standard wire sizes.

Core Insulation

Braided Fiber Glass with high temperature impregnation

No. of Cores

2, 4, 6, 8 or even more

Construction

Cores twisted

Outer Sheath

Braided Fiber Glass with high temperature impregnation

SS  JACKET

Optional Outside SS Metal braid

Color Coding

Confirms to EN 60751, supplied with color tracers

                        Optional High Temperature Impregnation. Impregnation maintained up to 200 C

                 Other sizes in SWG and also different construction in other stranded sizes are available on request  

FEW POPULAR RTD CABLE WIRE SIZES as per MIL16878

 

Sr. No.

Size in AWG

No. of strands/dia. of each strand (mm)

Parameters of conductor (Nominal)
(As per JSS 51034)

Nominal Dia. of Insulated Wire

Dia. (mm)

Cross section (sq. mm)

Resistance Ohm/km at 2 C

Elongation % (Min)

ET
(250 V) AC

E
(600 V ) AC

EE
(1000 V) AC

 

1.

26/7/34

7/0.16

0.48

0.1409

133.7

9.0

0.79

0.99

1.24

 

2.

24/7/32

7/0.2

0.60

0.2270

83.2

9.0

0.91

1.12

1.37

 

3.

24/19/36

19/0.13

0.63

0.2407

80.2

9.0

0.91

1.12

1.37

 

4.

22/7/30

7/0.25

0.75

0.3547

52.5

13.5

1.07

1.27

1.52

 

5.

22/19/34

19/0.16

0.80

0.3820

49.8

9.0

1.07

1.27

1.52

 

6.

20/7/28

7/0.32

0.97

0.5630

33.0

13.5

1.27

1.47

1.73

 

7.

20/19/32

19/0.2

1.00

0.6162

30.3

9.0

1.27

1.47

1.73

 


  

 

RTD Extension Wire Ceramic Yarn Insulated

RTD Extension Wire Rx CC

RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8,9  cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction. The main application of these wires is for extreme temperature conditions.

APPLICATIONS

PRODUCT FEATURES

      RTD Sensors & Extension Wires

         Continuous use up to 800 C

     RTD Autoclave

         Single exposure up to 1000C

      Medical Instruments & Scientific Equipments

        Good Thermal Durability & Strength

       Sensors, Load Cells & Pressure Transducers

         Flame Retardant

       Electronics & Communication Equipment

         Superior Abrasion Resistance

       Process Instrumentation

        Better flexibility


PRODUCT  SPECIFICTIONS:

Conductor

Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL 168780 & JSS 5103492, Refer Table for most popular & standard wire sizes.

Core Insulation

Braided Ceramic Fiber

No. of Cores

2, 4, 6, 8 or even more

Construction

Cores twisted

Outer Sheath

Braided Ceramic Fiber

SS  JACKET

Optional Outside SS Metal braid

Color Coding

Confirms to EN 60751, supplied with color tracers

 FEW STANDARD RTD CABLE WIRE SIZES as per MIL 16878

Sr. No.

Size in AWG

No. of strands/dia. of each strand (mm)

Parameters of conductor (Nominal)
(As per JSS 51034)

Nominal Dia. of Insulated Wire

Dia. (mm)

Cross section (sq. mm)

Resistance Ohm/km at 20oC

Elongation % (Min)

ET
(250 V) AC

E
(600 V ) AC

EE
(1000 V) AC

 

1.

26/7/34

7/0.16

0.48

0.1409

133.7

9.0

0.79

0.99

1.24

 

2.

24/7/32

7/0.2

0.60

0.2270

83.2

9.0

0.91

1.12

1.37

 

3.

24/19/36

19/0.13

0.63

0.2407

80.2

9.0

0.91

1.12

1.37

 

4.

22/7/30

7/0.25

0.75

0.3547

52.5

13.5

1.07

1.27

1.52

 

5.

22/19/34

19/0.16

0.80

0.3820

49.8

9.0

1.07

1.27

1.52

 

6.

20/7/28

7/0.32

0.97

0.5630

33.0

13.5

1.27

1.47

1.73

 

7.

20/19/32

19/0.2

1.00

0.6162

30.3

9.0

1.27

1.47

1.73

 














 

RTD Extruded WIRE

RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8, 9  cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction.

ELTEC PTFE Insulated RTD Extension wires conforms to US Military MIL 16878 and Indian defense specifications JSS 51034.92. As per these standards, these wires are classified in three main working voltage grades.

 HV TEST      

GRADE

SPARK TESTING

DIE ELECTRIC TESTING

ET (250 V)

2500 V ACrms

1500 V ACrms

E (600 V)

3400 V ACrms

2000 V ACrms

EE (1000 V)

5000 V ACrms

3000 V ACrms


APPLICATIONS

PRODUCT FEATURES

          RTD Sensors & Extension Wires

          Continuous use up to 90 C

          RTD Autoclave

          Good moisture, chemical & solvent resistance

          Medical Instruments & Scientific Equipments

          Good Thermal Durability & Strength

          Sensors, Load Cells & Pressure Transducers

          Flame Retardant

          Electronics & Communication Equipment

          Superior Abrasion Resistance

          Process Instrumentation

          Better flexibility

          Packaging

          Most economical & popular insulation


PRODUCT  SPECIFICTIONS:

Conductor

Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL 168780 & JSS 5103492, Refer Table for most popular & standard wire sizes.

Core Insulation

Flame Retardant PVC

No. of Cores

2, 4, 6, 8 or even more

Inner Sheath

Flame Retardant PVC

Construction

Parallel Conductors

Outer Sheath

Flame Retardant extruded FEP

Armored (Optional)

WIRE ARMORED or SS METAL OVERBRAID

Color Coding

Confirms to EN 60751

 

           Other sizes in SWG and also different construction in other stranded sizes are available on request                                                                                                  Other sizes in SWG and also different construction in other stranded sizes are available on request                                                                                                  Optional construction of twisted conductors & shieldin                                                                                                                                                                                    Duplex construction are also availabl                                                                                                                                                                                                                  Optional Color coding: IEC 605843, BS 1843, DIN 13711, JIS C 16101981, NFC 42334 as per requirement

 

 

RTD Extension Wires Rx SRSR

RTD Extension Wires Rx 2C SRSR

RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8, 9  cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction.

APPLICATIONS

PRODUCT FEATURES

          RTD Sensors & Extension Wires

            Continuous use up to 200 C

          RTD Autoclave

           Single exposure up to 240C

          Medical Instruments & Scientific Equipments

          Excellent Flexibility

          Sensors, Load Cells & Pressure Transducers

          Excellent softness

          Electronics & Communication Equipment

          Resistant to moisture

          Process Instrumentation

          Resistant to oil, solvent & chemicals

          Packaging

          Continuous use up to 105 C


PRODUCT  SPECIFICTIONS:

Conductor

Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL 168780 & JSS 5103492, Refer Table for most popular & standard wire sizes.

Core Insulation

Extruded Silicone Rubber

No. of Cores

2, 4, 6, 8 or even more

Construction

Parallel Conductors

Inner Sheath

Silicone Rubber

Armored (Optional)

WIRE ARMORED or SS METAL OVERBRAID

Color Coding

Confirms to EN 60751

 

    

          Other sizes in SWG and also different construction in other stranded sizes are available on request  

          Optional construction of twisted conductors & shielding 

          Duplex construction are also available

          Few Standard Conductor Sizes confirming to MIL 16878 & JSS 51034 are as per the table

FEW STANDARDRTD CABLE WIRE SIZES as per MIL 16878

                                

Sr. No.

Size in AWG

No. of strands/dia. of each strand (mm)

Parameters of conductor (Nominal)
(As per JSS 51034)

Nominal Dia. of Insulated Wire

Dia. (mm)

Cross section (sq. mm)

Resistance Ohm/km at 

Elongation % (Min)

ET
(250 V) AC

E
(600 V ) AC

EE
(1000 V) AC

 

1.

26/7/34

7/0.16

0.48

0.1409

133.7

9.0

0.79

0.99

1.24

 

2.

24/7/32

7/0.2

0.60

0.2270

83.2

9.0

0.91

1.12

1.37

 

3.

24/19/36

19/0.13

0.63

0.2407

80.2

9.0

0.91

1.12

1.37

 

4.

22/7/30

7/0.25

0.75

0.3547

52.5

13.5

1.07

1.27

1.52

 

5.

22/19/34

19/0.16

0.80

0.3820

49.8

9.0

1.07

1.27

1.52

 

6.

20/7/28

7/0.32

0.97

0.5630

33.0

13.5

1.27

1.47

1.73

 

7.

20/19/32

19/0.2

1.00

0.6162

30.3

9.0

1.27

1.47

1.73

 















RTD WIRE FEP

RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8, 9  cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction.

 ELTEC PTFE Insulated RTD Extension wires conforms to US Military 16878 and Indian defense specifications JSS 51034. As per these standards, these wires are classified in three main working voltage grades.

HV TEST

GRADE

SPARK TESTING

DIE ELECTRIC TESTING

ET (250 V)

2500 V AC

1500 V AC

E (600 V)

3400 V AC

2000 V AC

EE (1000 V)

5000 V AC

3000 V AC

 

APPLICATIONS

PRODUCT FEATURES

RTD Sensors & Extension Wires

    Continuous use up to 200 oC

RTD Autoclave

       Single exposure up to 400oC

Medical Instruments & Scientific Equipments

 Chemical Resistant

Sensors, Load Cells & Pressure Transducers

 Moisture Resistant

Electronics & Communication Equipment

  Flame Retardant

   Process Instrumentation

  Smoother surface finish

    Packaging

Good Electrical Properties

 

PRODUCT  SPECIFICATIONS:

Conductor

Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL 168780 & JSS 51034, Refer Table for most popular & standard wire sizes.

Core Insulation

Flame Retardant extruded  FEP

No. of Cores

2, 4, 6, 8 or even more

Construction

Twisted Conductor

Outer Sheath

Flame Retardant extruded FEP

SS  JACKET

Optional Outside SS Metal braid

Color Coding

Confirms to EN 60751

  Other sizes in SWG and also different construction in other stranded sizes are available on request

  Optional construction of twisted conductors & shielding

  Duplex construction are also available


FEW POPULAR RTD CABLE WIRE SIZES as per MIL  16878

 

Sr. No.

Size in AWG

No. of strands/dia. of each strand (mm)

Parameters of conductor (Nominal)
(As per JSS 51034)

Nominal Dia. of Insulated Wire

Dia. (mm)

Cross section (sq. mm)

Resistance Ohm/km at     C

Elongation % (Min)

ET
(250 V) AC

E
(600 V ) AC

EE
(1000 V) AC

 

1.

26/7/34

7/0.16

0.48

0.1409

133.7

9.0

0.79

0.99

1.24

 

2.

24/7/32

7/0.2

0.60

0.2270

83.2

9.0

0.91

1.12

1.37

 

3.

24/19/36

19/0.13

0.63

0.2407

80.2

9.0

0.91

1.12

1.37

 

4.

22/7/30

7/0.25

0.75

0.3547

52.5

13.5

1.07

1.27

1.52

 

5.

22/19/34

19/0.16

0.80

0.3820

49.8

9.0

1.07

1.27

1.52

 

6.

20/7/28

7/0.32

0.97

0.5630

33.0

13.5

1.27

1.47

1.73

 

7.

20/19/32

19/0.2

1.00

0.6162

30.3

9.0

1.27

1.47

1.73

 

  

  

Silicon Cable - 200 C

SILICON RUBBER

Silicone Rubber THERMOCOUPLE is ideal for application where greater flexibility & high humidity resistance is of prime importance. Silicone Rubber Insulated thermocouple wire is commonly used to link the thermocouple to control instrumentation. It may also be used to build the sensing point and can be used as THERMOCOUPLE SENSOR or used in manufacturing THERMOCOUPLE ASSEMBLIES or can used to connect to DATA LOGGERS via THERMOCOUPOLE CONNECTORS.


ConductorSolid or Multi stranded Original THERMOCOUPLE GRADE
Core InsulationSilicone Rubber Extruded
Core LayingParallel or twisted
No. of Pair1, 2 or more
ShieldingAlu. Mylar with drain wire or Tin Copper wire or SS etc.
Outer SheathSilicone Rubber Extruded
BraidingN.A.
Color Coding

As per IEC, ANSI, BS, DIN, NFC, JIS etc. Refer Table  

RTD Extension Wire Silicone Rubber Insulated

RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8, 9  cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction.

 

APPLICATIONS

PRODUCT FEATURES

      RTD Sensors & Extension Wires

          Continuous use up to 180 C

RTD Autoclave

          Single exposure up to 240C

Medical Instruments & Scientific Equipments

          Excellent Flexibility

    Sensors, Load Cells & Pressure Transducers

         Excellent softness

Electronics & Communication Equipment

          Resistant to moisture

    Process Instrumentation

      Resistant to oil, solvent & chemicals

  Packaging

          Continuous use up to 105 C

 

PRODUCT  SPECIFICATIONS:

Conductor

Silver Plated Copper wires sizes from 28 AWG to 20 AWG as per MIL 168780 & JSS 51034, Refer Table for most popular & standard wire sizes.

Core Insulation

Extruded Silicone Rubber

No. of Cores

2, 4, 6, 8 or even more

Construction

Twisted Conductors

Inner Sheath

Extruded Silicone Rubber

Armored (Optional)

WIRE ARMORED or SS METAL OVER BRAID

Color Coding

Confirms to EN 60751

 

Other sizes in SWG and also different construction in other stranded sizes are available on request

Optional construction of twisted conductors & shielding

Duplex construction are also available

Few Standard Conductor Sizes confirming to MIL 16878 & JSS 51034 are as per the table

FEW STANDARD RTD CABLE WIRE SIZES as per MIL W  16878

 

 

Sr. No.

Size in AWG

No. of strands/dia. of each strand (mm)

Parameters of conductor (Nominal)
(As per JSS 51034)

Nominal Dia. of Insulated Wire

Dia. (mm)

Cross section (sq. mm)

Resistance Ohm/km at 20oC

Elongation % (Min)

ET
(250 V) AC

E
(600 V ) AC

EE
(1000 V) AC

 

1.

26/7/34

7/0.16

0.48

0.1409

133.7

9.0

0.79

0.99

1.24

 

2.

24/7/32

7/0.2

0.60

0.2270

83.2

9.0

0.91

1.12

1.37

 

3.

24/19/36

19/0.13

0.63

0.2407

80.2

9.0

0.91

1.12

1.37

 

4.

22/7/30

7/0.25

0.75

0.3547

52.5

13.5

1.07

1.27

1.52

 

5.

22/19/34

19/0.16

0.80

0.3820

49.8

9.0

1.07

1.27

1.52

 

6.

20/7/28

7/0.32

0.97

0.5630

33.0

13.5

1.27

1.47

1.73

 

7.

20/19/32

19/0.2

1.00

0.6162

30.3

9.0

1.27

1.47

1.73

 

 

 

RTD Extension Wire

RTD Cables are used as an extension wire to transmit Signal from RTD Sensor to Control Unit. They are available in 2,3,4,6,8, 9  cores as per the requirement of RTD SENSOR design for Simplex & Duplex Construction.

 The most popular design is of PTFE Insulation & outer jacket of PTFE, GLASS FIBER & SILICONE RUBBER as per requirement. Metal over braid of SS & SPC, if required

 ELTEC PTFE Insulated RTD Extension wires conforms to US Military MIL - W - 16878 and Indian defense specifications JSS 51034. As per these standards, these wires are classified in three main working voltage grades.

 

GRADE

SPARK TESTING

DIE ELECTRIC TESTING

ET (250 V)

2500 V AC

1500 V AC

E (600 V)

3400 V AC

2000 V AC

EE (1000 V)

5000 V AC

3000 V AC

 

APPLICATIONS

PRODUCT FEATURES

   RTD Sensors & Extension Wires

        Continuous use up to 260 C

        RTD Autoclave

       Intermittent use up to 300 C

     Medical Instruments & Scientific Equipments

  High dielectric values

     Sensors, Load Cells & Pressure Transducers

Non flammable, non toxic

     Electronics & Communication Equipment

High strain & abrasion resistance

         Process Instrumentation

       Immune to agene, fungus

 


PRODUCT  SPECIFICTIONS:

Conductor

Soft Annealed silver plated or nickel plated copper wires as per MIL 16878, Refer Table

Core Insulation

Fused PTFE Tape , Fiber Glass, Silicone Rubber Extruded, Refer Ordering Code

No. of Pair or Triad

1, 2, 3 or more

Construction

Twisted

Outer Sheath

Fused PTFE Tape , Fiber Glass Insulated, Silicone Rubber Extruded, Refer Ordering Code

Screening

Silver Plated Copper wire  Braid or SS Over Metal Braid

Color Code

Confirms to EN 60751

 

FEW POPULAR RTD CABLE WIRE SIZES as per MIL - W -16878

 

Sr. No.

Size in AWG

No. of strands/dia. of each strand (mm)

Parameters of conductor (Nominal)
(As per JSS 51034)

Nominal Dia. of Insulated Wire

Dia. (mm)

Cross section (sq. mm)

Resistance Ohm/km at 20 oC

Elongation % (Min)

ET
(250 V) AC

E
(600 V ) AC

EE
(1000 V) AC

 

1.

26/7/34

7/0.16

0.48

0.1409

133.7

9.0

0.79

0.99

1.24

 

2.

24/7/32

7/0.2

0.60

0.2270

83.2

9.0

0.91

1.12

1.37

 

3.

24/19/36

19/0.13

0.63

0.2407

80.2

9.0

0.91

1.12

1.37

 

4.

22/7/30

7/0.25

0.75

0.3547

52.5

13.5

1.07

1.27

1.52

 

5.

22/19/34

19/0.16

0.80

0.3820

49.8

9.0

1.07

1.27

1.52

 

6.

20/7/28

7/0.32

0.97

0.5630

33.0

13.5

1.27

1.47

1.73

 

7.

20/19/32

19/0.2

1.00

0.6162

30.3

9.0

1.27

1.47

1.73

 

 

X


Back to top