AI-5X42 .
AI-5X42 .

AI-5X42 .

AI-5X42 . Specification

  • Data Capacity
  • 5000 results
  • Alarm
  • Audio and visual alert
  • Theory
  • Electrochemical (Fuel cell sensor)
  • Power Supply
  • DC 5V via USB
  • Temperature Range
  • -10C to +50C
  • Type
  • Alcohol Tester Breathalyzer
  • Display Type
  • 2.4 TFT Color Screen
  • Memory
  • 5000 test results
  • Accuracy
  • 0.005 mg/L at 0.500 mg/L
  • Size
  • 160 x 75 x 35 mm
  • Resolution
  • 0.001 mg/L
  • Battery
  • Rechargeable Li-ion 3.7V, 2000mAh
  • GPS
  • Optional
  • Net Weight
  • 320 g
  • Standby Time
  • More than 12 hours
  • Interface
  • USB / RS232
  • Measuring Range
  • 0.000 4.000 mg/L (BrAC)
  • Includes
  • Mouthpieces, Carrying Case
 
 

About AI-5X42 .

AI-5X42

Features


  • Low cost, Effective, Easy to useDigital Temperature Controller
  • 4-Digit, Single Row Display
  • Selectable sensor input (T/C : J, K,R,S & RTD) from keyboard
  • Programmable Lower & Upper set point limits
  • Programmable control action ON-OFF/T.P control
  • Programmable hysteresis in ON-OFF mode
  • Programmable time delay to activate output in ON-OFF mode
  • Selectable heat/cool logic in ON-OFF control mode
  • Four different alarm modes (Low/High/Band/Deviation)
  • Alarm latch / Alarm inhibit function
  • Second output for auxiliary control/alarm mode
  • Program lock function (To prevent unauthorized tampering)
  • Universal supply voltage ranges from 90 To 270 VAC
  • Available in 5 Standard DIN sizes


Specification

SeriesAI-5X42
Display
Type7 Segment LED
No. of Digit4 Digit Single Row
LED IndicationOutput Status
Display heightTable No.1
Input Specification
Measurement
InputThermocouple J, K, R, S;
RTD: pt-100
Indication Accuracy0.3% FS
ResolutionJ, K, R, S : 1°C
RTD : 1°C / 0.1 °C
Output Specification
Set Points
No. of Set Points2
SP Range LimitJ : 0 to 760 °C K : -99 to 1200 °C
R : 0 to 1700 °C
S : 0 to 1700 °C
RTD : -100 to 450 °C
RTD.1 : -99.9 to 450.0 °C
Output 1
Relay / SSR DriveTo be Specified (Factory Set)
Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
SSR Drive12 VDC @ 50 mA
Output 2
Relay / SSR DriveTo be Specified (Factory Set)
Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
SSR Drive12 VDC @ 50 mA
Functional Specification
Control ActionT.P or ON/OFF
Control Parameter
HysteresisJ, K, R, S, RTD : 1 to 99 °C
RTD.1: 0.1 to 99.9 °C
Delay0 to 500 Sec
Proportional Band0.5 to 99.9°C
Cycle Time0.5 to 100.0 Sec
Aux. ControlAbsolute / Deviation
Output 2 Function
AlarmLow /High /Band /Deviation
Alarm Hysteresis, K, R, S, RTD : 1 to 99 °C
RTD.1 : 0.1 to 99.9 °C
General Specification
Supply Voltage
90 - 270 VAC/DC
24 VAC/DC (OPTIONAL)
Temperature
Operating0 - 50°C
Storage-20° to 75°C


High Accuracy Fast Alcohol Detection

Using an electrochemical fuel cell sensor, the AI-5X42 delivers accurate alcohol readings within seconds. The device warms up in 15 seconds and provides results in as little as 5 seconds, making it perfect for high-throughput screening environments like checkpoints and professional settings.


Seamless Data Management and Connectivity

The breathalyzer includes storage capacity for 5,000 results, and supports easy data transfer to a PC via USB or RS232. The optional GPS feature and compatible PC software make result management comprehensive and traceable, fitting well into professional reporting workflows.


Robust Design for All Environments

Operable in humidity levels of up to 95% RH and temperature ranges between -10C to +50C, the AI-5X42 is built for demanding conditions. Its portable size, rechargeable battery, and included carrying case ensure it remains convenient and reliable wherever you need it.

FAQs of AI-5X42 .:


Q: How do I operate the AI-5X42 alcohol tester for accurate results?

A: To use the AI-5X42, power it on and allow a 15-second warm-up. Attach a disposable mouthpiece, then instruct the subject to blow steadily into the device. Analysis completes in about 5 seconds, with results displayed on the 2.4-inch TFT color screen.

Q: What is the recommended calibration interval and what does it entail?

A: It is recommended to calibrate the AI-5X42 every 6 months. Calibration involves using certified alcohol standards to ensure ongoing measurement accuracy. Professional calibration services or qualified technicians should perform this process.

Q: When should the devices rechargeable battery be recharged, and how long does it typically last on standby?

A: Recharge the built-in Li-ion 3.7V, 2000mAh battery using the provided USB cable when battery levels are low. The device offers more than 12 hours of standby time per charge, ensuring continuous operation across multiple testing sessions.

Q: Where can I access and manage stored test results from the device?

A: Stored results (up to 5,000 entries) can be accessed directly on the device or transferred to a computer using USB or RS232. Compatible PC software supports data analysis, archival, and reporting for further management.

Q: What kind of environmental conditions can the AI-5X42 operate in?

A: This device functions reliably within a temperature range of -10C to +50C and up to 95% relative humidity, making it suitable for diverse climate conditions encountered in field and workplace applications.

Q: How does the built-in alarm system enhance user safety?

A: The AI-5X42 features both audio and visual alerts that trigger when alcohol levels exceed preset thresholds, ensuring prompt awareness and action when safety limits are breached.

Q: What are the main benefits of choosing the AI-5X42 breathalyzer?

A: The AI-5X42 offers fast, reliable, and highly accurate breath alcohol measurements, large data storage, compatibility with professional software, and robust operation in challenging environments. It is ideal for exporters, manufacturers, and suppliers seeking dependable alcohol testing solutions in India.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Data Loggers Category

AI-5X41 .

AI-5X41 .

Interface : Other, USB/RS232

Type : Other, AI5X41 Humidity & Temperature Data Logger

Display Type : LCD

Includes : Other, Logger, software CD, USB cable, battery, user manual

Measuring Range : 30C to 60C, 0%RH to 100%RH

Memory : 32000 set data storage

TIMER KEYBOARD BASED KTM-XX3 Series

TIMER KEYBOARD BASED KTM-XX3 Series

Interface : Other, Keypad Buttons

Type : Other, Keyboard Based Timer

Display Type : Other, Digital LED

Includes : Other, Wall Mounting Accessories

Measuring Range : 1 second to 99 hours

Memory : 7 days (Programmable)

TIMER KEYBOARD BASED KTM-XX8 Series

TIMER KEYBOARD BASED KTM-XX8 Series

Interface : Other, Digital Keypad

Type : Other, Keyboard Based Timer

Display Type : Other, 7Segment LED

Includes : Other, Main Unit, Manual

Measuring Range : 1 second to 999 hours

Memory : NonVolatile Storage

PID TE,PERATURE CONTROLLER AI-X00

PID TE,PERATURE CONTROLLER AI-X00

Interface : Other, Relay Output, SSR, Analog (varies by model)

Type : Other, PID Temperature Controller

Display Type : Other, Dual 4Digit 7 Segment LED

Includes : Other, Controller Unit, Instruction Manual

Measuring Range : Thermocouple or RTD input dependent; typically 199C to 1800C

Memory : NonVolatile Memory



Back to top