Data Loggers

Data Loggers are the electronic equipments that are used to record data regarding the temperature of the industrial devices to maintain the system in an optimal state for excellent performance. There are various types of such controlling devices availed by us in many different designs and capabilities. Data Loggers availed by us are equipped with top quality electronic components for excellent performance. These devices can operate independently of a computer and are capable to handle hundreds of inputs. They are provided with a soft touch button keyboard and a digital display to feed different values to the system.

Data Logger And Paperless Recorder

Price: 7500 INR /Piece

  • Application INDUSTRIAL
  • Dimension (L*W*H) 96 X 96 Millimeter (mm)
  • Display Type LED
  • GPS Yes
  • Interface Other
  • Minimum Order Quantity 1
  • Price 7500 INR
  • Product Type Data Logger And Paperless Recorder
  • Type Other, Data Logger And Paperless Recorder
  • Unit of Measure Piece/Pieces
  • Unit of Price Piece/Pieces

Data Logger And Paperless Recorder is a digital monitoring device that is commonly used in wide range of commercial as well as industrial grade automated machines. It is designed and developed as per the electronic engineering standards that make it energy efficient and accurate in operation. This smart and intelligent device also helps to analyze and validate the recorded data. The circuit elements of the offered Data Logger And Paperless Recorder are enclosed in sturdy hard plastic case that helps to prevent damages from moisture, humidity, water, and chemical attacks.

Specification

Model Name/Number

AL LOGGER

Type Of Data Logger

Digital Data Logger

Usage/Application

Industrial

Parameter To Be Monitored

Temperature, Pressure, Level, Humidity

Interface

RS-485, 2 Wire, Half Duplex

Export Of Data

Excel

Display

Standard

Dimension

96 X 96

  

Technical Details 

Humidity and Temperature Data Logger

Price: 10000 INR /Piece

  • Application INDUSTRIAL
  • Color Black & White
  • Dimension (L*W*H) 60 x 38 x 18,5 mm Millimeter (mm)
  • Display Type LCD
  • GPS Yes
  • Interface Other
  • Minimum Order Quantity 5
  • Price 10000 INR
  • Type Humidity Data Logger
  • Unit of Measure Piece/Pieces
  • Unit of Price Piece/Pieces
The Humidity and Temperature Data Logger is a professional-grade device designed to provide accurate readings of temperature and humidity levels in a variety of industrial settings. With a sleek and compact design, the device is equipped with a LCD display, GPS, and a black and white color scheme. Measuring 60 x 38 x 18.5 mm, the device is perfect for use in tight spaces. The Humidity and Temperature Data Logger is a reliable and precise tool for monitoring environmental conditions.

FAQ :

Q: What is a Humidity and Temperature Data Logger?
A: A Humidity and Temperature Data Logger is a device used to measure and record temperature and humidity levels over a period of time.

Q: What are the specifications of the Humidity and Temperature Data Logger?
A: The Humidity and Temperature Data Logger has a GPS, a black and white LCD display, other type of interface, 60 x 38 x 18,5 mm Millimeter (mm) in dimension and is suitable for industrial applications.

Q: Does the Humidity and Temperature Data Logger have GPS?
A: Yes, the Humidity and Temperature Data Logger has GPS.

Specification

Model Name/Number

TESTO 174H

Type Of Data Logger

Digital Data Logger

Usage/Application

Vaccine Freezer

Parameter To Be Monitored

Temperature

Interface

USB Interface

Export Of Data

PDF

Display

Digital

Brand

TESTO

Model

174 H

Usage

Laboratory

Communication

With computer through USB

 

Technical Details 

PID TEMPERATURE CONTROLLER AI-7X82-Series

  • Accuracy 0.5% of full scale
  • Alarm Programmable Output, Relay 3A at 220V AC
  • Battery Not Required (Powered by external supply)
  • Data Capacity Parameter storage for settings
  • Display Type Other, 4-Digit 7 Segment LED Display
  • Includes Other, Controller Unit, User Manual
  • Interface Other, Relay/SSR Output, Sensor Input Terminals
  • Measuring Range Depends on sensor type (typically -1999 to 9999)
  • Memory Non-volatile memory (parameter retention)
  • Net Weight Approx. 350g
  • Power Supply 85-265V AC/DC, 50/60Hz
  • Resolution 1C or 0.1C (Depending on sensor)
  • Size 96mm x 96mm x 65mm (Panel Cutout: 92mm x 92mm)
  • Standby Time Continuous Operation
  • Temperature Range Configurable, typically -199C to 999C
  • Theory Other , Proportional-Integral-Derivative (PID) Control
  • Type Other, PID Temperature Controller
  • Unit of Measure ,

AI-7X82-Series

Features


  • Low cost, Effective, Easy to use PID Temperature Controller
  • 4-Digit display Dual Row (4-Digit for PV & 4-Digit for SV)
  • Selectable sensor input (T/C : J,K,R,S & RTD) from keyboard
  • Programmable Lower & Upper set point limits
  • Programmable control action ON-OFF/PID control
  • Programmable hysteresis in ON-OFF mode
  • Programmable time delay to activate output in ON-OFF mode
  • Selectable heat/cool logic in ON-OFF control mode
  • Four different alarm modes (Low/High/Band/Deviation)
  • Alarm latch / Alarm inhibit function
  • Programmable soak timer
  • Four different start modes for soak timer
  • Selectable time base for soak timer
  • Selectable soak timer direction
  • Settable soak time delay
  • Selectable End of soak strategy (heater off/alarm/both)
  • Program lock function (To prevent unauthorized tampering)
  • Universal supply voltage ranges from 90 To 270 VAC
  • Available in 5 Standard DIN sizes


Specification

SeriesAI-7X82
Display
Type7 Segment LED
No. of Digit4 Digit Dual Row
LED IndicationOutput Status, Soak Time
Display heightTable No.1
Input Specification
Measurement
InputThermocouple J, K, R, S;
RTD: pt-100
Indication Accuracy0.3% FS
ResolutionJ, K, R, S : 1C
RTD : 1C / 0.1 C
Output Specification
Set Points
No. of Set Points2
SP Range LimitJ : 0 to 760 C K : -99 to 1200 C
R : 0 to 1700 C
S : 0 to 1700 C
RTD : -100 to 450 C
RTD.1 : -99.9 to 450.0 C
Output 1
Relay / SSR DriveTo be Specified (Factory Set)
Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
SSR Drive12 VDC @ 50 mA
Output 2
Relay / SSR DriveTo be Specified (Factory Set)
Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
SSR Drive12 VDC @ 50 mA
Functional Specification
Control ActionPID or ON/OFF
Control Parameter
HysteresisJ, K, R, S, RTD : 1 to 99 C
RTD.1: 0.1 to 99.9 C
Delay0 to 500 Sec
Proportional Band0.5 to 99.9C
Cycle Time0.5 to 100.0 Sec
Aux. ControlAbsolute / Deviation
Output 2 Function
AlarmLow /High /Band /Deviation
Soak Timer1-9999 mins.
AlarmLow /High /Band /Deviation
General Specification
Supply Voltage
90 - 270 VAC/DC
24 VAC/DC (OPTIONAL)
Temperature
Operating0 - 50C
Storage-20 to 75C
Humidity (Non-condensing)95 % RH


Flexible Control Output Selection

Choose between Relay, SSR, or Analog 4-20mA/0-10V output to match a wide array of industrial application needs. This flexibility enhances integration with various devices and systems, ensuring optimum temperature management reliability.


Versatile Sensor Input Compatibility

Accepts multiple sensor types, including Thermocouples (K, J, T, R, S) and RTD (Pt100), providing adaptability for different temperature measurement requirements in industrial settings. Sensor selection is easily configurable for precise regulation.


Efficient and User-Friendly Operation

Push button digital programming allows straightforward setup and parameter adjustment. High brightness 4-digit LED provides clear readings, while the IP54-rated panel ensures durability in tough industrial environments.

FAQs of PID TEMPERATURE CONTROLLER AI-7X82-Series:


Q: How do I select the appropriate control output for my application with the AI-7X82-Series PID Temperature Controller?

A: You can choose between Relay, SSR, or Analog 4-20mA/0-10V control outputs based on your systems requirements. The output type is selectable via the devices settings, making it adaptable for various heating or cooling equipment integration.

Q: What sensors are compatible with the AI-7X82-Series controller, and how does the sensor input selection process work?

A: The controller supports Thermocouple types K, J, T, R, S and RTD Pt100 sensors. Sensor selection is digitally programmed using the push-button interface, allowing users to configure the input to match their specific temperature measurement needs.

Q: When should I use the automatic versus manual control mode on the AI-7X82-Series?

A: Automatic mode utilizes PID control for precise temperature regulation, ideal for processes requiring consistent thermal management. Manual mode allows the operator to adjust the output directly, suitable for testing, troubleshooting, or special operational scenarios.

Q: Where can the AI-7X82-Series PID Temperature Controller be installed?

A: This unit is designed for panel mounting, fitting into a standard panel cutout of 92mm x 92mm. Its IP54 front panel protection makes it suitable for harsh industrial environments, including manufacturing plants and process control panels.

Q: What is the process for programming settings and storing parameters on this controller?

A: Settings are programmed through user-friendly push buttons on the front panel. Parameters are stored in non-volatile memory, ensuring all configuration data is retained even during power loss or shutdown.

Q: How does the RS485 communication feature benefit industrial applications?

A: The optional RS485 interface allows for remote monitoring and integration into centralized control systems. This enhances data communication and process automation, especially in large-scale environments.

Q: What are the advantages of using the AI-7X82-Series controller for industrial temperature management?

A: This controller offers precise regulation (0.5% full scale), flexible configurations, rapid response time, reliable performance, and robust protection, making it a valuable solution for continuous operation in demanding industrial settings.

PID TEMPERATURE CONTROLLER AI-7X42-Series

  • Accuracy 0.2% of FS 1 digit
  • Alarm 1 or 2 relay output alarms selectable
  • Display Type Other, Dual 4-digit 7-segment LED Display
  • Includes Other, Controller Unit, Instruction Manual
  • Interface Other, Universal Input (Thermocouple, RTD, mV, V, mA)
  • Measuring Range -1999 to 9999 (depends on input type)
  • Memory Non-volatile EEPROM
  • Net Weight Approx. 350 g
  • Power Supply 100-240 V AC (50/60Hz)
  • Resolution 1C / 0.1C
  • Size 96 x 48 x 110 mm
  • Temperature Range -199C to 1800C (input dependent)
  • Theory Other , Proportional-Integral-Derivative (PID)
  • Type Other, PID Temperature Controller
  • Unit of Measure ,

AI-7X42-Series

Features


  • Low cost, Effective, Easy to use PID Temperature Controller
  • 4 Digit Single Row Display
  • Selectable sensor input (T/C : J,K,R,S & RTD) from keyboard
  • Programmable Lower & Upper set point limits
  • Programmable control action ON-OFF/PID control
  • Programmable hysteresis in ON-OFF mode
  • Programmable time delay to activate output in ON-OFF mode
  • Selectable heat/cool logic in ON-OFF control mode
  • Four different alarm modes (Low/High/Band/Deviation)
  • Alarm latch / Alarm inhibit function
  • Second output for auxiliary control/alarm mode
  • Program lock function (To prevent unauthorized tampering)
  • Universal supply voltage ranges from 90 To 270 VAC
  • Available in 5 Standard DIN sizes Specification


Specification

SeriesAI-7X42
Display
Type7 Segment LED
No. of Digit4 Digit Single Row
LED IndicationOutput Status
Display heightTable No.1
Input Specification
Measurement
InputThermocouple J, K, R, S;
RTD: pt-100
Indication Accuracy0.3% FS
ResolutionJ, K, R, S : 1C
RTD : 1C / 0.1 C
Output Specification
Set Points
No. of Set Points2
SP Range LimitJ : 0 to 760 C K : -99 to 1200 C
R : 0 to 1700 C
S : 0 to 1700 C
RTD : -100 to 450 C
RTD.1 : -99.9 to 450.0 C
Output 1
Relay / SSR DriveTo be Specified (Factory Set)
Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
SSR Drive12 VDC @ 50 mA
Output 2
Relay / SSR DriveTo be Specified (Factory Set)
Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
SSR Drive12 VDC @ 50 mA
Functional Specification
Control ActionPID or ON/OFF
Control Parameter
HysteresisJ, K, R, S, RTD : 1 to 99 C
RTD.1: 0.1 to 99.9 C
Delay0 to 500 Sec
Proportional Band0.5 to 99.9C
Cycle Time0.5 to 100.0 Sec
Output 2 Function
Aux. ControlAbsolute / Deviation
AlarmLow /High /Band /Deviation
Alarm HysteresisJ, K, R, S, RTD : 1 to 99 C
RTD.1 : 0.1 to 99.9 C
General Specification
Supply Voltage
H90 - 270 VAC/DC
24 VAC/DC (OPTIONAL)
Temperature
Operating0 - 50C
Storage-20 to 75C
Humidity (Non-condensing)95 % RH


Versatile Input & Output Solutions

The AI-7X42-Series controller accommodates various input types, including K, J, T, E, R, S, B, N, WRe thermocouples, Pt100 and Cu50 RTDs, as well as voltage and mA inputs. Its flexible output configurationRelay, SSR, or Currentenables seamless integration into different systems, ensuring adaptability across multiple industrial environments.


Robust Performance & Intuitive Operation

Designed for high accuracy and reliability, the controller offers a rapid 250ms sampling cycle and memory retention through non-volatile EEPROM. Its panel mount design fits a cutout size of 92 x 45 mm, complemented by a user-friendly digital keypad. The dual LED display ensures clear monitoring of status and settings even in challenging working conditions.

FAQs of PID TEMPERATURE CONTROLLER AI-7X42-Series:


Q: How do I install and set up the AI-7X42-Series temperature controller?

A: The device is designed for panel mounting with a cutout size of 92 x 45 mm. Installation involves securing the controller in the panel, connecting the appropriate inputs (thermocouple, RTD, or signal), and configuring settings via the digital keypad. Refer to the included instruction manual for step-by-step wiring and parameter setting guidance.

Q: What input types and temperature ranges does this controller support?

A: The controller accepts thermocouples (K, J, T, E, R, S, B, N, WRe), RTDs (Pt100, Cu50), and voltage/mA signals. Supported temperature range varies based on the input type, from as low as -199C up to 1800C. The measuring range is -1999 to 9999 depending on the sensor used.

Q: When should I use Auto PID or Manual PID control modes?

A: Auto PID mode is suitable for processes requiring precise and continuous temperature control with automatic tuning. Manual PID is ideal for operations that benefit from user-defined control adjustments. ON/OFF mode can be chosen for simpler applications or backup control.

Q: Where can this temperature controller be used effectively?

A: The AI-7X42-Series is suitable for industrial applications such as process heating, ovens, plastic machinery, laboratory equipment, and HVAC systems. Its wide input compatibility and panel mount design make it adaptable to a variety of control systems.

Q: What is the process for configuring output alarms on this controller?

A: Output alarms can be set using the digital keypad. You may select 1 or 2 relay output alarms depending on process requirements. Alarm parameters such as set point and function are programmable through the menu as outlined in the instruction manual.

Q: How does the controller ensure long-term data retention and stability?

A: Settings and parameters are stored on non-volatile EEPROM memory, ensuring retention even after power loss. The device operates reliably in environments with up to 85% humidity and within a storage temperature range of -10C to 60C.

Q: What are the key benefits of using the AI-7X42-Series PID controller?

A: The controller delivers precise temperature regulation, supports a wide array of sensors, and offers a sturdy interface with multiple output options. Its fast response time, easy configuration, and durable panel-mounted design with IP54 front protection make it an excellent choice for both exporters and manufacturers in demanding industrial settings.

TIMER KEYBOARD BASED KTM-XX3 Series

  • Accuracy 0.5% of setting
  • Alarm Buzzer Output
  • Battery Built-in rechargeable (Ni-MH)
  • Data Capacity Multiple program settings (up to 50)
  • Display Type Other, Digital LED
  • GPS No
  • Includes Other, Wall Mounting Accessories
  • Interface Other, Keypad Buttons
  • Measuring Range 1 second to 99 hours
  • Memory 7 days (Programmable)
  • Net Weight Approx. 250 g
  • Power Supply 220 VAC, 50Hz
  • Resolution 1 second
  • Size 100 mm x 85 mm x 50 mm
  • Standby Time Up to 48 hours (battery mode)
  • Temperature Range 0C to 50C
  • Theory Other , Electronic Count Down Timer
  • Type Other, Keyboard Based Timer
  • Unit of Measure ,

KTM-XX3 Series


Features

  • Low cost, Effective, Easy to use Keyboard based Digital timer
  • Programmable timer start modes to suit various applications
  • Programmable Up/Down counting
  • Programmable Front Reset
  • Programmable Output 2 functions : Auxiliary contact/End of cycle/Instant contact
  • Multiple Time Range: From 0.01 Sec. to 999 Hrs.
  • Time Setting via keyboard
  • Configuration at power on (To prevent unauthorized tampering)
  • Available in 5 Standard DIN sizes
  • 3-Digit display
  • Programmable ON Delay/Interval/Cyclic/Forward-Reverse mode
  • Programmable Auto Reset/Latch Output
  • Programmable Memory Backup
  • High Accuracy: 0.05% of Full scale (Repeat Accuracy: 0.01%)
  • Time base selection via keyboard
  • Independent time base for both cycles in Cyclic mode
  • Universal supply voltage ranges from 90 To 270 VAC
  • Specification

    KTM-3D
    SeriesEconomical keyboard Counter
    DisplayType7 segment LED
    No. of Digits4 Digits, Single Row
    LED IndicationOutput Status ; Batch/AR Time
    DimensionsTable no : 1
    Input Specification
    Start InputPower On, Pulse (Edge Trigger),Front Start (Programmable)
    Reset InputFront Key & Rear Terminal (Potential free)
    AccuracySetting : 0.05% of Full scale Repeat : 0.01%
    Output Specification
    No. Of Outputs2
    Output 1Relay / SSRFactory settings
    Relay Contact Rating5 A @ 250V AC/30V DC resistive
    SSR12 VDC @ 50mA
    Output 2Relay / SSRFactory settings
    Relay Contact Rating5 A @ 250V AC/30V DC resistive
    SSR12 VDC @ 50mA
    Configuration Parameters
    Delay ModesOn Delay/Interval/Cyclic ON time first/Cyclic OFF time first/Cyclic Hold-Forward-Hold-Reverse-Hold
    Time Range9.99 Sec ; 99.9 Sec ; 999 Sec
    9.59 Min : Sec
    99.9 Min ; 999 Min
    9.59 Hrs : Min
    99.9 Hrs ; 999 Hrs
    Timer Start ModesPower On Start
    Pulse Start (Edge Triggered)
    Front Start Pulse Start (Edge +Level )
    Programmable No. of CycleApplicable in On delay/Off delay CY1 & CY2 Mode Only
    Timing Accuracy0.05 % Full scale
    Time Base SelectionThrough Keyboard
    Front Panel ResetEnable/Disable
    Memory BackupEnable/Disable
    Output 2 ConfigurableAuxiliary Contact
    Batch Mode
    General Specification
    Supply Voltage90 - 270 VAC/DC
    24 VAC/DC (OPTIONAL)
    TemperatureOperating0 - 50C
    Storage-20 to 75C
    Humidity (Non-condensing)95 % RH
    Weight


    Precision and Scheduling Flexibility

    The KTM-XX3 Series Timer allows users to program up to 50 distinct on/off cycles every day, providing exceptional control over automation tasks. Its 1-second resolution and 0.5% settings accuracy guarantee precise operation, vital for environments demanding consistent workflow automation and reliable lighting management.


    Durable and Secure Performance

    Engineered with a flame-retardant ABS plastic housing and an IP20 ingress protection rating, this timer offers robust durability and safety in industrial environments. The device supports both surface and panel mounting options for versatile installation, maintaining operational integrity in various setups.


    User-Friendly Interface and Extended Utility

    Equipped with a digital LED display and keypad buttons, the KTM-XX3 Timer is straightforward to program and monitor. Its 7-day programmable memory accommodates multiple settings, while the built-in battery ensures up to 48 hours of uninterrupted operation during power interruptions.

    FAQs of TIMER KEYBOARD BASED KTM-XX3 Series:


    Q: How do I program multiple on/off events on the KTM-XX3 Series Timer?

    A: Programming up to 50 on/off cycles per day is easily managed through the keypad interface. Simply use the buttons to set times for activation and deactivation, with a resolution ranging from 1 second to 99 hours.

    Q: What applications can the KTM-XX3 Timer be used for?

    A: This timer is suitable for industrial automation, lighting control, and process automation, offering customizable scheduling for machinery, lighting fixtures, and equipment requiring timed operation.

    Q: When should I use surface or panel mounting for this timer?

    A: Surface mounting is recommended for quick, external installation, while panel mounting is ideal for integrated setups within control boards, ensuring stability and protection depending on your environment.

    Q: Where can the KTM-XX3 Series Timer be installed?

    A: The device can be installed in any industrial or commercial area that meets its operating conditions (0C to 50C, <95% RH non-condensing), using the included wall mounting accessories for secure placement.

    Q: What is the process for recovering a scheduled program after a power outage?

    A: Its built-in rechargeable Ni-MH battery maintains settings and supports up to 48 hours of standby time, automatically preserving programmed events and ensuring seamless operation when power is restored.

    Q: How does using the KTM-XX3 Series Timer benefit overall system automation?

    A: By reliably managing scheduled events with high accuracy, the timer streamlines automation, cuts manual intervention, boosts efficiency, and reduces energy consumption in industrial and lighting systems.

    TIMER PUSH WHEEL BASED DTM-XX3 Series

    • Accuracy 1% of Full Scale
    • Alarm End Time Relay Contact Output
    • Battery No battery required (Power supply operated)
    • Data Capacity N/A (Mechanical Timer)
    • Display Type Other, Mechanical Counter Display
    • Includes Other, Main Unit, Mounting Bracket, User Manual
    • Interface Other, Rotary Dial
    • Measuring Range 0 to 9999 seconds/minutes (selectable)
    • Memory Non-Volatile Memory
    • Net Weight Approx. 310g
    • Power Supply 220-240V AC, 50/60Hz
    • Resolution 1 second/minute
    • Size 48 x 96 x 83 mm
    • Standby Time Continuous Operation
    • Temperature Range -10C to +55C
    • Theory Other , Mechanical/Relay Switch Timer
    • Type Other, Push Wheel Timer
    • Unit of Measure ,

    DTM-XX2 Series


    Features

  • Low cost, Effective, Easy to use Pushwheel based Digital timer
  • Programmable ON Delay/Interval mode via DIP switch
  • Multiple Time Range: From 0.1 Sec. to 99 Hrs.
  • Time Setting via High Quality Push wheel switches
  • Universal supply voltage ranges from 90 To 270 VAC
  • 2-Digits, Single Row Display
  • High Accuracy: 0.05% of Full scale (Repeat Accuracy: 0.01%)
  • Time base selection via DIP switches
  • Configuration at power on (To prevent unauthorized tampering)
  • Available in 2 Standard DIN sizes
  • Specification

    DTM-2D
    SeriesEconomical keyboard Counter
    DisplayType7 segment LED
    No. of Digits4 Digits, Single Row
    LED IndicationOutput Status ; Batch/AR Time
    DimensionsTable no : 1
    Input Specification
    Start InputPower On, Pulse (Edge Trigger),Front Start (Programmable)
    Reset InputFront Key & Rear Terminal (Potential free)
    AccuracySetting : 0.05% of Full scale Repeat : 0.01%
    Output Specification
    No. Of Outputs2
    Output 1Relay / SSRFactory settings
    Relay Contact Rating5 A @ 250V AC/30V DC resistive
    SSR12 VDC @ 50mA
    Output 2Relay / SSRFactory settings
    Relay Contact Rating5 A @ 250V AC/30V DC resistive
    SSR12 VDC @ 50mA
    Configuration Parameters
    Delay ModesOn Delay/Interval
    Time Range9.9 Sec ; 99 Sec
    9.9 Min ; 99 Min
    9.9 Hrs ; 99 Hrs
    Timing Accuracy0.05 % Full scale
    Front Panel ResetEnable only
    Output 2 ConfigurableAuxiliary Contact
    General Specification
    Supply Voltage90 - 270 VAC/DC
    24 VAC/DC (OPTIONAL)
    TemperatureOperating0 - 50C
    Storage-20 to 75C
    Humidity (Non-condensing)95 % RH
    Weight


    High Durability and Reliability

    Built to deliver over 100,000 electrical cycles and 10 million mechanical cycles, the DTM-XX3 ensures consistent performance across demanding environments. The device supports continuous operation and integrates effective end-time relay contact outputs for dependable process control.


    Flexible, Precise Timing Control

    Users benefit from a wide measuring range of 09999 seconds or minutes, selectable via the intuitive push wheel and rotary dial interface. The timers 1% full scale accuracy and mechanical counter display make it ideal for applications where precise, repeatable time settings are essential.


    Simple Installation and User Interface

    The timer is equipped with a panel mount, screw terminal connections, and comes complete with a mounting bracket and user manual. Its straightforward setup and robust design accommodate various industrial use cases, making integration easy and maintenance minimal.

    FAQs of TIMER PUSH WHEEL BASED DTM-XX3 Series:


    Q: How do I set the timing operation on the DTM-XX3 Series push wheel timer?

    A: You can set the timing by rotating the push wheel and using the rotary dial to select your desired duration, ranging from 0 to 9999 seconds or minutes. The mechanical counter display shows the set value for quick verification.

    Q: What are the main benefits of a mechanical timer like the DTM-XX3 Series over electronic timers?

    A: Mechanical timers like the DTM-XX3 Series offer high reliability, non-volatile memory (settings retained without power), longer life spans, and no need for battery replacement, making them ideal for continuous industrial operation.

    Q: When should I use automatic or manual reset modes on this timer?

    A: Use automatic reset for repetitive timing cycles required in ongoing processes. Manual reset is more suitable when a process needs controlled restart after each timing operation, often used for safety or process audits.

    Q: Where can I install the TIMER PUSH WHEEL BASED DTM-XX3 Series in an industrial setup?

    A: It is designed for panel mounting in control panels or machinery. Ensure the front panel is accessible for setting adjustments and the unit is installed within the recommended temperature range of -10C to +55C.

    Q: What is the process for wiring this timer, and what connections are available?

    A: Wiring is done through durable screw terminals with clear markings in the included manual. The timer supports direct connection to a 220-240V AC, 50/60Hz supply and offers 1 C/O (SPDT) relay contact output for alarm or control integration.

    Q: How does the timer benefit industrial automation and process control?

    A: The DTM-XX3 Series enhances process automation by providing precise, repeatable ON delay control. Its reliability, easy interface, and accurate timing enable improved safety, efficiency, and consistency in automated systems.

    PID TEMPERATURE CONTROLLER AI-7X81-Series

    • Unit of Measure ,

    AI-7X81-Series

    Features


    • Low cost, Effective, Easy to use PID Temperature Controller
    • 4 Digits Dual Row Display (4-Digits for PV & 4-Digits for SV)
    • Selectable sensor input (T/C : J,K,R,S & RTD) from keyboard
    • Programmable Lower & Upper set point limits
    • Programmable control action ON-OFF/PID control
    • Programmable hysteresis in ON-OFF mode/li>
    • Programmable time delay to activate output in ON-OFF mode
    • Selectable heat/cool logic in ON-OFF control mode
    • User selectable Relay Or SSR DriveOutput
    • Program lock function (To prevent unauthorized tampering)
    • Universal supply voltage ranges from 90 To 270 VAC
    • Available in 5 Standard DIN sizes Specification


    Specification

    SeriesAI-7X81
    Display
    Type7 Segment LED
    No. of Digit4 Digit Dual Row
    LED IndicationOutput Status
    Display heightTable No.1
    Input Specification
    Measurement
    InputThermocouple J, K, R, S;
    RTD: pt-100
    Indication Accuracy0.3% FS
    ResolutionJ, K, R, S : 1C
    RTD : 1C / 0.1 C
    Output Specification
    Set Points
    No. of Set Points1
    SP Range LimitJ : 0 to 760 C K : -99 to 1200 C
    R : 0 to 1700 C
    S : 0 to 1700 C
    RTD : -100 to 450 C
    RTD.1 : -99.9 to 450.0 C
    Output 1
    Relay / SSR DriveUser Selectable
    Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
    SSR Drive2 VDC @ 50 mA
    Functional Specification
    Control ActionPID or ON/OFF
    Control Parameter
    HysteresisJ, K, R, S, RTD : 1 to 99 C
    RTD.1 : 0.1 to 99.9 C
    Delay0 to 500 Sec
    Proportional Band0.5 to 99.9C
    Cycle Time0.5 to 100.0 Sec
    General Specification
    Supply Voltage
    H90 - 270 VAC/DC
    24 VAC/DC (OPTIONAL)
    Temperature
    Operating0 - 50C
    Storage-20 to 75C
    Humidity (Non-condensing)95 % RH

    PID TE,PERATURE CONTROLLER AI-7X42-Series

    • Accuracy 0.3% FS
    • Alarm Configurable high/low temperature alarms
    • Data Capacity Parameter settings retained in non-volatile memory
    • Display Type Other, Dual 4-digit bright LED Display
    • Includes Other, Controller unit, screw terminal connectors
    • Interface Other, Relay Output, SSR Output, Analog Output (optional)
    • Measuring Range Depends on sensor type (e.g., K-type: 0C to 1200C)
    • Memory Non-volatile memory for parameter settings
    • Net Weight Approx. 250g
    • Power Supply 85265V AC/DC Universal input
    • Resolution 1C (configurable as per sensor)
    • Size 48 x 48 x 110 mm (Panel mount)
    • Standby Time Continuous operation (No battery) supplied via mains
    • Temperature Range -1999C to 9999C depending on sensor
    • Theory Other , Proportional-Integral-Derivative (PID) Control
    • Type Other, Universal Digital PID Temperature Controller
    • Unit of Measure ,

    AI-7X42-Series

    Features


    • Low cost, Effective, Easy to use PID Temperature Controller
    • 4 Digit Single Row Display
    • Selectable sensor input (T/C : J,K,R,S & RTD) from keyboard
    • Programmable Lower & Upper set point limits
    • Programmable control action ON-OFF/PID control
    • Programmable hysteresis in ON-OFF mode
    • Programmable time delay to activate output in ON-OFF mode
    • Selectable heat/cool logic in ON-OFF control mode
    • Four different alarm modes (Low/High/Band/Deviation)
    • Alarm latch / Alarm inhibit function
    • Second output for auxiliary control/alarm mode
    • Program lock function (To prevent unauthorized tampering)
    • Universal supply voltage ranges from 90 To 270 VAC
    • Available in 5 Standard DIN sizes Specification


    Specification

    SeriesAI-7X42
    Display
    Type7 Segment LED
    No. of Digit4 Digit Single Row
    LED IndicationOutput Status
    Display heightTable No.1
    Input Specification
    Measurement
    InputThermocouple J, K, R, S;
    RTD: pt-100
    Indication Accuracy0.3% FS
    ResolutionJ, K, R, S : 1C
    RTD : 1C / 0.1 C
    Output Specification
    Set Points
    No. of Set Points2
    SP Range LimitJ : 0 to 760 C K : -99 to 1200 C
    R : 0 to 1700 C
    S : 0 to 1700 C
    RTD : -100 to 450 C
    RTD.1 : -99.9 to 450.0 C
    Output 1
    Relay / SSR DriveTo be Specified (Factory Set)
    Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
    SSR Drive12 VDC @ 50 mA
    Output 2
    Relay / SSR DriveTo be Specified (Factory Set)
    Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
    SSR Drive12 VDC @ 50 mA


    Versatile Control Modes

    The AI-7X42-Series allows you to select between PID, ON-OFF, or AUTO tuning control methods to optimize temperature management for diverse applications. This flexibility ensures reliable regulation, whether for simple or complex industrial processes.


    Wide Input Compatibility

    Easily interface with different sensor types, including thermocouples, RTDs, voltage, and current. This universal input capability enables precise temperature measurement across varying equipment setups and industries.


    User-Friendly Features

    Enjoy an intuitive dual 4-digit bright LED display, easy panel mounting, and quick parameter setup. The non-volatile memory safeguards your settings, supporting uninterrupted usage without constant reconfiguration.


    Secure and Durable Design

    Constructed from ABS flame-retardant material and protected by an IP20 rating, the controller is designed for operational safety and long service life in demanding environments.

    FAQs of PID TE,PERATURE CONTROLLER AI-7X42-Series:


    Q: How can I select and configure the input type for the AI-7X42-Series controller?

    A: To set up the input type, access the controllers parameter menu, where you can choose from thermocouple, RTD, voltage, or current inputs depending on your sensor. Refer to the user manual for the specific codes and configuration steps.

    Q: What benefits does auto-tuning offer compared to standard PID or ON-OFF control?

    A: Auto-tuning automatically determines optimal PID parameters for your system, reducing manual setup and enhancing control precision. This is especially advantageous when process dynamics are unknown or subject to change.

    Q: Where should the AI-7X42-Series controller be installed for optimal performance?

    A: Install the controller in a panel-mounted position with sufficient ventilation, away from excessive humidity (3585% RH) and ambient temperatures above 50C. This setup ensures protection against dust and stable operation.

    Q: When should I use the alarm feature, and how do I configure it?

    A: Use the configurable high/low temperature alarms to alert operators of deviations from set thresholds. Access the alarm settings via the menu and input your desired alarm values as per your process requirements.

    Q: What happens to my parameter settings if there is a power outage?

    A: The AI-7X42-Series controller employs non-volatile memory, which securely retains all parameter settings even during power loss, eliminating the need to reprogram after outages.

    Q: How is the output type (relay, SSR, analog) chosen and what does it influence?

    A: Select the output type (relay, SSR, 4-20mA, or 0-10V) during installation or configuration based on your control hardware. The chosen output determines how the controller communicates with your final control element, such as heaters or actuators.

    TIMER PUSH WHEEL BASED DTM-XX2 Series

    • Accuracy 0.01% of set time
    • Alarm Relay output on completion
    • Battery Not required (Mains powered)
    • Display Type Other, 7-segment LED digital display
    • Includes Other, Mounting bracket, instruction manual
    • Interface Other, Front mechanical push wheel
    • Measuring Range 0.01 sec to 99.99 hrs (model dependent)
    • Memory Non-volatile memory for settings retention
    • Net Weight Approx. 250 g
    • Power Supply 110V/230V AC, 50/60Hz or 24V DC (model dependent)
    • Resolution 0.01 sec
    • Size 72 x 72 mm panel size (depth varies per model)
    • Standby Time Continuous operation on mains
    • Temperature Range 0C to 55C operating
    • Theory Other , Electronic time counting
    • Type Other, Push Wheel Digital Timer
    • Unit of Measure ,

    DTM-XX2 Series


    Features

  • Low cost, Effective, Easy to use Pushwheel based Digital timer
  • Programmable ON Delay/Interval mode via DIP switch
  • Multiple Time Range: From 0.1 Sec. to 99 Hrs.
  • Time Setting via High Quality Push wheel switches
  • Universal supply voltage ranges from 90 To 270 VAC
  • 2-Digits, Single Row Display
  • High Accuracy: 0.05% of Full scale (Repeat Accuracy: 0.01%)
  • Time base selection via DIP switches
  • Configuration at power on (To prevent unauthorized tampering)
  • Available in 2 Standard DIN sizes
  • Specification

    DTM-2D
    SeriesEconomical keyboard Counter
    DisplayType7 segment LED
    No. of Digits4 Digits, Single Row
    LED IndicationOutput Status ; Batch/AR Time
    DimensionsTable no : 1
    Input Specification
    Start InputPower On, Pulse (Edge Trigger),Front Start (Programmable)
    Reset InputFront Key & Rear Terminal (Potential free)
    AccuracySetting : 0.05% of Full scale Repeat : 0.01%
    Output Specification
    No. Of Outputs2
    Output 1Relay / SSRFactory settings
    Relay Contact Rating5 A @ 250V AC/30V DC resistive
    SSR12 VDC @ 50mA
    Output 2Relay / SSRFactory settings
    Relay Contact Rating5 A @ 250V AC/30V DC resistive
    SSR12 VDC @ 50mA
    Configuration Parameters
    Delay ModesOn Delay/Interval
    Time Range9.9 Sec ; 99 Sec
    9.9 Min ; 99 Min
    9.9 Hrs ; 99 Hrs
    Timing Accuracy0.05 % Full scale
    Front Panel ResetEnable only
    Output 2 ConfigurableAuxiliary Contact
    General Specification
    Supply Voltage90 - 270 VAC/DC
    24 VAC/DC (OPTIONAL)
    TemperatureOperating0 - 50C
    Storage-20 to 75C
    Humidity (Non-condensing)95 % RH
    Weight


    Versatile Timing for Industrial Applications

    Supporting both ON delay and interval modes, the DTM-XX2 Series timer adapts seamlessly to varying process requirements, making it perfect for control panels, automation, and manufacturing environments. Its selectable timing options suit multiple applications, from machinery sequencing to batch processing.


    Robust Design with Reliable Operation

    Designed with a flame-retardant ABS plastic body and front IP40 protection, this timer withstands rigorous industrial conditions. The panel mounting and compact size (72 x 72 mm) ensure easy installation, while continuous operation on mains power keeps processes running smoothly.


    User-Friendly Interface and Accurate Performance

    The mechanical push wheel interface and bright 7-segment LED display make setup and monitoring straightforward. With non-volatile memory for parameter retention and high accuracy (0.01%), settings remain secure and reliable for all timing needs.

    FAQs of TIMER PUSH WHEEL BASED DTM-XX2 Series:


    Q: How does the TIMER PUSH WHEEL BASED DTM-XX2 Series ensure user-friendly operation?

    A: This timer features a mechanical front push wheel interface and a clear 7-segment LED display, allowing users to easily set and monitor timing parameters. Its panel-mount design further simplifies installation and accessibility.

    Q: What contact specifications does the relay output provide for industrial loads?

    A: The timer utilizes a single SPDT (1 C/O) relay output, rated at 5A for 230V AC resistive loads, providing reliable switching capability widely suited to industrial automation needs.

    Q: When is it advantageous to use the manual and automatic reset functions?

    A: Manual reset is ideal for processes requiring operator confirmation before restarting, while automatic reset benefits repetitive or cycle-based operations, allowing seamless and continuous timing without intervention.

    Q: Where should I install the DTM-XX2 timer for optimal performance?

    A: The timer is designed for panel mounting within control cabinets. Its IP40 front protection and robust ABS housing make it suitable for factory floors, machinery panels, and process control consoles.

    Q: What is the process for adjusting timing settings and what benefit does the memory function provide?

    A: Users adjust timing by turning the mechanical push wheels on the panel. The non-volatile memory stores these settings, ensuring that configured values are retained even after a power interruption, minimizing downtime and setup effort.

    Q: How is timing accuracy maintained, and what measurement range does the timer support?

    A: The DTM-XX2 Series achieves high accuracy (0.01%), supporting measurement ranges from 0.01 seconds to 99.99 hours, selectable per model. This guarantees precise timing for varied industrial processes.

    Q: What are the advantages of using this timer in humid environments?

    A: With a humidity operating range of 35% to 85% RH (non-condensing) and flame-retardant housing, the timer remains dependable and safe in typical industrial environments, reducing the risk of malfunction due to environmental stress.

    TIMER KEYBOARD BASED KTM-XX8 Series

    • Accuracy 0.01%
    • Alarm Buzzer
    • Battery Rechargeable Lithium Battery
    • Data Capacity Up to 100 Events
    • Display Type Other, 7-Segment LED
    • GPS No
    • Includes Other, Main Unit, Manual
    • Interface Other, Digital Keypad
    • Measuring Range 1 second to 999 hours
    • Memory Non-Volatile Storage
    • Net Weight 350 grams
    • Power Supply 220V AC or Battery
    • Resolution 1 second
    • Size 120 x 100 x 60 mm
    • Standby Time Up to 48 hours
    • Temperature Range -10C to 50C
    • Theory Other , Electronic Timer, Digital Control
    • Type Other, Keyboard Based Timer
    • Unit of Measure ,

    KTM-XX8 Series


    Features

  • Low cost, Effective, Easy to use Keyboard based Digital timer
  • 4-Digits, Dual Row Display [Upper 3-Digit: Run time & Lower 3-Digit: Set time]
  • Programmable ON Delay/Interval/Cyclic/Forward-Reverse mode [with Hold time]
  • Programmable total time in Forward-Reverse mode
  • Programmable Front Reset
  • Programmable Output 2 functions : Auxiliary contact/End of cycle/Instant contact
  • Multiple Time Range: From 0.01 Sec. to 999 Hrs.
  • Time Setting via keyboard
  • Configuration at power on (To prevent unauthorized tampering)
  • Available in 5 Standard DIN sizes
  • Programmable timer start modes to suit various applications
  • Programmable No. of cycle in Cyclic mode
  • Programmable Up/Down counting
  • Programmable Auto Reset/Latch Output
  • Programmable Memory Backup
  • High Accuracy: 0.05% of Full scale (Repeat Accuracy: 0.01%)
  • Time base selection via keyboard
  • Independent time base for both cycles in Cyclic mode
  • Universal supply voltage ranges from 90 To 270 VAC
  • Specification

    KTM-8D
    SeriesEconomical keyboard Counter
    DisplayType7 segment LED
    No. of Digits4 Digits, Single Row
    LED IndicationOutput Status ; Batch/AR Time
    DimensionsTable no : 1
    Input Specification
    Start InputPower On, Pulse (Edge Trigger),Front Start (Programmable)
    Reset InputFront Key & Rear Terminal (Potential free)
    AccuracySetting : 0.05% of Full scale Repeat : 0.01%
    Output Specification
    No. Of Outputs3
    Output 1Relay / SSRFactory settings
    Relay Contact Rating5 A @ 250V AC/30V DC resistive
    Output 2Relay / SSRFactory settings
    Relay Contact Rating5 A @ 250V AC/30V DC resistive
    SSR12 VDC @ 50mA
    Output 3Relay / SSRFactory settings
    Relay Contact Rating5 A @ 250V AC/30V DC resistive
    SSR12 VDC @ 50mA
    Configuration Parameters
    Delay ModesOn Delay/Interval/Cyclic ON time first/Cyclic OFF time first/Cyclic Hold-Forward-Hold-Reverse-Hold
    Time Range9.99 Sec ; 99.9 Sec ; 999 Sec
    9.59 Min : Sec
    99.9 Min ; 999 Min
    9.59 Hrs : Min
    99.9 Hrs ; 999 Hrs
    Timer Start ModesPower On Start
    Pulse Start (Edge Triggered)
    Front Start Pulse Start (Edge +Level )
    Programmable No. of CycleApplicable in On delay/Off delay CY1 & CY2 Mode Only
    Timing Accuracy0.05 % Full scale
    Time Base SelectionThrough Keyboard
    Front Panel ResetEnable/Disable
    Memory BackupEnable/Disable
    Output 2 ConfigurableAuxiliary Contact
    Batch Mode
    Output 3Applicable in CY1, CY2 & CY3 Mode
    General Specification
    Supply Voltage90 - 270 VAC/DC
    24 VAC/DC (OPTIONAL)
    TemperatureOperating0 - 50C
    Storage-20 to 75C
    Humidity (Non-condensing)95 % RH
    Weight


    Advanced Time Control Features

    The KTM-XX8 Series delivers robust time management capabilities with its digital keypad input, relay control outputs, and a wide measuring range. Its intuitive keypad and LED display simplify programming, making it ideal for process automation.


    Reliable Construction and Protection

    Crafted from ABS polycarbonate with protection class IP20, this timer resists dust and general mechanical wear. Its engineered to maintain performance in humid conditions up to 85% RH and temperatures from -10C to 50C.


    Flexible Power and Event Logging

    With options for 220V AC or rechargeable battery power, the KTM-XX8 ensures continuous operation. Its non-volatile memory allows for up to 100 event recordings, supporting historical data and repeatable automation tasks.

    FAQs of TIMER KEYBOARD BASED KTM-XX8 Series:


    Q: How is the KTM-XX8 Series timer installed?

    A: The KTM-XX8 Series timer is designed for panel mounting. Users simply secure the unit in a suitable control panel, following the installation guidelines provided in the manual for safe and effective setup.

    Q: What operation modes are available on this timer?

    A: This timer supports both countdown and count-up modes, allowing for flexible timing control based on application requirements. Selection and setting modes are managed easily via the built-in digital keypad.

    Q: When should I use the audible and visual indicators?

    A: Audible (buzzer) and visual (LED) indicators are ideal for alerting users upon completion of timed events or reaching preset thresholds, enhancing safety and notification in industrial or process environments.

    Q: Where can the KTM-XX8 Series be used?

    A: Suitable for indoor industrial and commercial settings, this timer is effective in panels where accurate time control is needed. Its IP20 protection allows use in areas protected from direct dust and moisture exposure.

    Q: What is the process for setting the timer?

    A: Time settings are configured directly using the digital keypad. Users may enter the desired timing duration (from 1 second up to 999 hours), select the operation mode, and initiate the timer based on their specific application.

    Q: How does the non-volatile memory benefit users?

    A: Non-volatile memory retains up to 100 timed event records even during power loss, ensuring historical data and settings are preserved for operational continuity and easy recall of previous configurations.

    Q: What are the advantages of using a rechargeable lithium battery?

    A: The rechargeable lithium battery provides up to 48 hours of standby operation in the event of power outages, supporting uninterrupted timing functionality and safeguarding your ongoing processes.

    TIMER KEYBOARD BASED EC-XX6-Serise

    • Accuracy 0.01%
    • Alarm Programmable relay output
    • Battery Not required (AC powered)
    • Data Capacity Program memory for multiple setpoints
    • Display Type Other, LED Numeric Digital Display
    • Includes Other, Main unit, Keyboard interface, Manual
    • Interface Other, Push-button keyboard interface
    • Measuring Range 0.1 seconds to 9999 hours (model dependent)
    • Memory Non-volatile memory retention
    • Net Weight Approx. 300 grams
    • Power Supply 220-240 V AC / 50-60 Hz
    • Resolution 0.1 sec / 1 sec selectable
    • Size Compact Panel Mount (model based)
    • Standby Time Continuous operation (AC supply based)
    • Temperature Range 0C to 55C
    • Theory Other , Electronic timer logic
    • Type Other, Digital Timer (Keyboard Based)
    • Unit of Measure ,

    EC-XX6-Serise


    Features

  • Low cost, Effective, Easy to use Keyboard based Digital Counter
  • 6-Digits, Single Row Display
  • Programmable Input Count Speed
  • Programmable Front Reset
  • Programmable Scale factor 1 to 99
  • Available 12 VDC Sensor Supply ( Short circuit protected )
  • Memory retention up to 10 years
  • Configuration at power on (To prevent unauthorized tampering)
  • Universal supply voltage ranges from 90 To 270 VAC
  • Available in 3 Standard DIN sizes
  • Specification

    EC-6D
    SeriesEconomical keyboard Counter
    DisplayType7 segment LED
    No. of Digits6 Digits, Single Row
    DimensionsTable no : 1
    Input Specification
    Control InputsCountProximity (NPN/PNP)
    Potential Free Contact
    Reset230 VAC Pulse (Optional)
    Front Switch (Programmable)
    Remote Reset (via rear terminals)
    Configuration Parameters
    Scale Factor1 to 99 (Divider)
    Count Range0 to 999999 Counts
    Memory RetentionUpto 10 years
    Count SpeedUpto 1KHz
    Memory BackupEnable/Disable
    General Specification
    Supply Voltage90 - 270 VAC/DC
    24 VAC/DC (OPTIONAL)
    TemperatureOperating0 - 50C
    Storage-20 to 75C
    Humidity (Non-condensing)95 % RH
    Weight


    Industrial Automation Made Simple

    The EC-XX6-Series digital timer streamlines timing operations in industrial environments. With intuitive keyboard programming and up to 8 settable cycles, users can automate complex processes effortlessly. Compact design and easy mounting options ensure seamless integration into control panels, minimizing downtime during installation.


    Precision Timing and Reliable Output

    Boasting a resolution selectable between 0.1 sec and 1 sec, and an impressive accuracy of 0.01%, this timer delivers dependable timing performance. The programmable relay output ensures that alarms and operations are actuated exactly as scheduled, making it ideal for industries requiring meticulous time management.


    User-Friendly Interface and Robust Construction

    The push-button keyboard interface offers straightforward configuration, suitable for both new and experienced operators. Its flame-retardant ABS plastic housing and IP20-rated front panel protect internal components, while the non-volatile memory ensures that program settings are always retainedeven during power outages.

    FAQs of TIMER KEYBOARD BASED EC-XX6-Serise:


    Q: How can I install the EC-XX6-Series timer in my control panel?

    A: The EC-XX6-Series timer supports DIN rail or panel mount installation. Simply follow the mounting instructions provided in the manual to securely attach it to your panel or DIN rail, ensuring proper alignment and electrical connections.

    Q: What are the main benefits of using a keyboard-based digital timer in industrial automation?

    A: This timer allows precise programming of up to 8 cycles via an easy-to-use keyboard interface. Non-volatile memory keeps settings safe, and the LED numeric display enables straightforward monitoring, ensuring accurate and efficient time-dependent operations.

    Q: What is the process for programming the timers cycles and setpoints?

    A: Using the push-button keyboard interface, enter the desired timing intervals and configure each cycle based on your process needs. Refer to the included manual for step-by-step guidance, and review the LED display for confirmation after programming.

    Q: When should I use the relay output feature in my automation setup?

    A: Relay outputs (NO/NC contacts, 5A @ 240V AC) are ideal when you need to control alarms, actuators, or other devices based on programmed timing events. Activate relay actions according to process requirements to automate operations safely.

    Q: Where can the EC-XX6-Series timer be used effectively?

    A: This timer is designed for environments such as manufacturing plants, process control systems, and other industrial facilities requiring automated, time-dependent operations. Its flame-retardant casing and robust power supply make it adaptable to various applications.

    Q: What level of protection does the front panel offer and why is this important for industrial settings?

    A: The front panel is rated IP20, which protects against accidental contact with internal components. While not waterproof, this rating is sufficient for most panel installations, minimizing hazards and maintaining operational integrity in controlled indoor environments.

    PID TE,PERATURE CONTROLLER AI-X00

    • Accuracy 0.5% of full scale 1 digit
    • Alarm Configurable Alarm Output
    • Display Type Other, Dual 4-Digit 7 Segment LED
    • Includes Other, Controller Unit, Instruction Manual
    • Interface Other, Relay Output, SSR, Analog (varies by model)
    • Measuring Range Thermocouple or RTD input dependent; typically -199C to 1800C
    • Memory Non-Volatile Memory
    • Net Weight Approx. 300-500g (model dependent)
    • Power Supply 100-240V AC, 50/60Hz
    • Resolution 1C or 0.1C (selectable by model)
    • Size 96 x 96 x 100 mm (varies as per model)
    • Temperature Range Input dependent, typically -199C to 1800C
    • Theory Other , Proportional-Integral-Derivative (PID) Control
    • Type Other, PID Temperature Controller
    • Unit of Measure ,

    AI-X00

    Features


    • Low cost, Effective, Easy to use PID Temperature Controller
    • 4 Digits Dual Row Display (4-Digits for PV & 4-Digits for SV)
    • Selectable sensor input (T/C : J,K,R,S & RTD) from keyboard
    • Programmable Lower & Upper set point limits
    • Programmable control action ON-OFF/PID control
    • Four different alarm modes (Low/High/Deviation low/Deviation High)
    • Program lock function (to prevent unauthorized tampering)
    • Universal supply voltage ranges from 90 to 270 VAC
    • Available in 4 Standard DIN sizes


    Specification

    SeriesAI-X00
    Display
    Type7 Segment LED
    No. of Digit4 Digit Dual Row
    LED IndicationOutput Status,Alarm Status, Tuning Status
    Display heightTable No.1
    Input Specification
    Measurement
    InputThermocouple : K,J,E,S,T,B,R ;
    RTD : Pt-100 
    Linear : 0-10 / 2-10 VDC
    Indication Accuracy0.2% FS
    Resolution0.1C (Up to 99.9C) OR 1C
    UnitsCentigrade (C)
    Output Specification
    Set Points
    No. of Set Points1
    SP Range LimitK-Type : -50 to 1350 C
    J-Type : -50 to 1000 C
    E-Type : -50 to 1000 C
    S-Type : -50 to 1750 C
    B-Type : 0 to 1800 C
    R-Type : -20 to 1750 C
    Pt-100 : -199.9 to 600.0 C
    Output 1
    Relay / SSR Drive /4-20 mAeTo be Specified (Factory Set)
    Relay Contact Rating3 A @ 250 VAC/30 VDC resistive
    SSR Drive12 VDC @ 30 mA
    Linear4-20 mA(Maximum Load 300 ohms)
    Alarm
    No of Alarm1 or 2
    Alarm ModesLow / High / Deviation High / Deviation Low
    Output typeRelay(3 Amp @230 VAC)
    functions Specification
    Control Parameter
    AlgorithmPID With Fuzzy Logic
    Control ModePID Or ON-OFF (Programmable)
    Proportional Band0 to 999.9 C
    Integral time0 to 3600 Sec
    Derivative time0 to 999 Sec
    Cycle Time0.5 to 300 Sec
    Hysteresis0 to 200 C
    General Specification
    Supply Voltage
    H90 - 270 VAC/DC
    24 VAC/DC (OPTIONAL)
    Temperature
    Operating0 - 50C
    Storage-20 to 75C
    Humidity (Non-condensing)95 % RH


    Universal Input Compatibility

    The AI-X00 PID Temperature Controller accommodates a broad spectrum of input types, including T/C, RTD, mA, and mV depending on your model. This flexibility ensures that it suits a wide array of applications, adapting easily to different process requirements and industrial setups.


    Precise Control and Configurable Outputs

    With selectable control outputsrelay, SSR, or analog (4-20mA, 0-10V)the AI-X00 guarantees accurate, reliable temperature regulation. Users benefit from PID, ON/OFF, or manual controller modes and auto-tuning for simplified setup and enhanced stability.


    User-Friendly Operation and Robust Build

    Engineered for convenience, the controller features easy-to-read dual 4-digit LED displays and a straightforward panel-mount design. Rated IP54 at the front, it withstands challenging environments, providing reliable operation between 0C to 50C and up to 85% relative humidity.

    FAQs of PID TE,PERATURE CONTROLLER AI-X00:


    Q: How does the auto-tuning function benefit temperature control processes?

    A: Auto-tuning streamlines the PID parameter setup, automatically optimizing control parameters for your process. This minimizes overshoot and enhances stability, leading to improved accuracy and consistent temperature regulation without requiring extensive manual calibration.

    Q: What input and output types does the AI-X00 controller support?

    A: The AI-X00 accepts universal inputs, such as thermocouple (T/C), RTD, mA, or mV, based on the model. Output options include relay, SSR, or analog (4-20mA, 0-10V), offering flexibility for integration with various control systems and applications.

    Q: When should I use single versus dual set-point models?

    A: Choose a single set-point model for basic applications requiring one control value, or a dual set-point model when you need to switch between two temperatures or use advanced control strategies, such as heating and cooling within a process.

    Q: Where is the AI-X00 suitable for installation?

    A: The panel mount design and IP54-rated front make the AI-X00 ideal for most industrial environments, particularly where front protection from dust and splashes is needed. It operates best in ambient temperatures from 0C to 50C with up to 85% non-condensing humidity.

    Q: What is the process for configuring alarms on the controller?

    A: Alarm outputs are configurable via the controllers menu. Once the control parameters are set, users can define alarm points for temperature thresholds or deviations, ensuring timely notification and protection of critical equipment or processes.

    Q: How does non-volatile memory enhance reliability?

    A: Non-volatile memory retains all parameter settings, alarm configurations, and calibration data even after a power outage, eliminating the need for repeated setup and ensuring seamless operation when power is restored.

    AI-5X41 .

    • Accuracy 0.3C (Temp), 3%RH (Humidity)
    • Alarm Upper and lower limit alarm
    • Battery 3.6V lithium battery
    • Data Capacity 32000 readings
    • Display Type LCD
    • GPS No
    • Includes Other, Logger, software CD, USB cable, battery, user manual
    • Interface Other, USB/RS232
    • Measuring Range -30C to 60C, 0%RH to 100%RH
    • Memory 32000 set data storage
    • Net Weight 65 g
    • Power Supply 3.6V lithium battery
    • Resolution 0.1C; 0.1%RH
    • Size 120 x 37 x 23 mm
    • Standby Time Up to 12 months
    • Temperature Range -30C to 60C
    • Theory Other , Electronic Sensor
    • Type Other, AI-5X41 Humidity & Temperature Data Logger
    • Unit of Measure ,

    AI-5X41

    Features


    • Low cost, Effective, Easy to useDigital Temperature Controller
    • 4 Digit Single Row Display
    • Selectable sensor input (T/C : J,K,R,S & RTD) from keyboard
    • Programmable Lower & Upper set point limits
    • Programmable control action ON-OFF/T.P control
    • Programmable hysteresis in ON-OFF mode
    • Programmable time delay to activate output in ON-OFF mode
    • Selectable heat/cool logic in ON-OFF control mode
    • User selectable Relay Or SSR DriveOutput
    • Program lock function (To prevent unauthorized tampering)
    • Universal supply voltage ranges from 90 To 270 VAC
    • Available in 5 Standard DIN sizes Specification


    Specification

    SeriesAI-5X41
    Display
    Type7 Segment LED
    No. of Digit4 Digit Single Row
    LED IndicationOutput Status
    Display heightTable No.1
    Input Specification
    Measurement
    InputThermocouple J, K, R, S;
    RTD: pt-100
    Indication Accuracy0.3% FS
    ResolutionJ, K, R, S : 1C
    RTD : 1C / 0.1 C
    Output Specification
    Set Points
    No. of Set Points1
    SP Range LimitJ : 0 to 760 C K : -99 to 1200 C
    R : 0 to 1700 C
    S : 0 to 1700 C
    RTD : -100 to 450 C
    RTD.1 : -99.9 to 450.0 C
    Output 1
    Relay / SSR DriveUser Selectable
    Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
    SSR Drive2 VDC @ 50 mA
    Functional Specification
    Control ActionT.P or ON/OFF
    Control Parameter
    HysteresisJ, K, R, S, RTD : 1 to 99 C
    RTD.1 : 0.1 to 99.9 C
    Delay0.5 to 99.9C
    Cycle Time0.5 to 100.0 Sec
    General Specification
    Supply Voltage
    H90 - 270 VAC/DC
    24 VAC/DC (OPTIONAL)
    Temperature
    Operating0 - 50C
    Storage-20 to 75C
    Humidity (Non-condensing)95 % RH
    Dimensions & WeightTable no : 2


    Versatile Environmental Monitoring

    The AI-5X41 data logger adapts to various settings with its wide sampling interval, user-defined recording modes, and configurable alarms. Its durable IP65-rated case withstands harsh and humid environments, making it suitable for industrial, laboratory, and transport applications.


    Comprehensive Data Management

    Equipped with Windows-compatible software, the AI-5X41 makes data retrieval and analysis straightforward. Users can easily export collected readings in CSV format via USB or RS232 interface, enabling seamless integration with reporting tools.

    FAQs of AI-5X41 .:


    Q: How is the sampling interval set on the AI-5X41 data logger?

    A: The sampling interval can be adjusted between 10 seconds and 24 hours using the included Windows-compatible software, allowing flexible monitoring depending on your requirements.

    Q: What steps are involved in starting a recording session?

    A: You can initiate data logging either immediately or by setting a timer through the software. Choose from start/stop, continuous, or cyclic recording modes based on your application needs.

    Q: When is user calibration recommended, and how is it performed?

    A: User calibration helps maintain measurement accuracy, especially after long-term use. It can be carried out easily using the provided software, following the instructions in the user manual to ensure reliable data.

    Q: Where can the AI-5X41 be utilized most effectively?

    A: This data logger is ideal for controlled environments such as laboratories, storage facilities, and transportation containersanywhere precise temperature and humidity tracking is required.

    Q: What process is used for data export and analysis?

    A: Recorded data is quickly transferred to a computer via USB or RS232 connection. The software allows exporting readings in CSV format, making further analysis and reporting simple and efficient.

    Q: How do the upper and lower limit alarms benefit users?

    A: Configurable alarms on the AI-5X41 notify users if readings exceed set boundaries, ensuring prompt attention to potential environmental excursions that might affect sensitive products or materials.

    AI-5X42 .

    • Accuracy 0.005 mg/L at 0.500 mg/L
    • Alarm Audio and visual alert
    • Battery Rechargeable Li-ion 3.7V, 2000mAh
    • Data Capacity 5000 results
    • Display Type Other, 2.4 TFT Color Screen
    • GPS Other, Optional
    • Includes Other, Mouthpieces, Carrying Case
    • Interface Other, USB / RS232
    • Measuring Range 0.000 4.000 mg/L (BrAC)
    • Memory 5000 test results
    • Net Weight 320 g
    • Power Supply DC 5V via USB
    • Resolution 0.001 mg/L
    • Size 160 x 75 x 35 mm
    • Standby Time More than 12 hours
    • Temperature Range -10C to +50C
    • Theory Other , Electrochemical (Fuel cell sensor)
    • Type Other, Alcohol Tester Breathalyzer
    • Unit of Measure ,

    AI-5X42

    Features


    • Low cost, Effective, Easy to useDigital Temperature Controller
    • 4-Digit, Single Row Display
    • Selectable sensor input (T/C : J, K,R,S & RTD) from keyboard
    • Programmable Lower & Upper set point limits
    • Programmable control action ON-OFF/T.P control
    • Programmable hysteresis in ON-OFF mode
    • Programmable time delay to activate output in ON-OFF mode
    • Selectable heat/cool logic in ON-OFF control mode
    • Four different alarm modes (Low/High/Band/Deviation)
    • Alarm latch / Alarm inhibit function
    • Second output for auxiliary control/alarm mode
    • Program lock function (To prevent unauthorized tampering)
    • Universal supply voltage ranges from 90 To 270 VAC
    • Available in 5 Standard DIN sizes


    Specification

    SeriesAI-5X42
    Display
    Type7 Segment LED
    No. of Digit4 Digit Single Row
    LED IndicationOutput Status
    Display heightTable No.1
    Input Specification
    Measurement
    InputThermocouple J, K, R, S;
    RTD: pt-100
    Indication Accuracy0.3% FS
    ResolutionJ, K, R, S : 1C
    RTD : 1C / 0.1 C
    Output Specification
    Set Points
    No. of Set Points2
    SP Range LimitJ : 0 to 760 C K : -99 to 1200 C
    R : 0 to 1700 C
    S : 0 to 1700 C
    RTD : -100 to 450 C
    RTD.1 : -99.9 to 450.0 C
    Output 1
    Relay / SSR DriveTo be Specified (Factory Set)
    Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
    SSR Drive12 VDC @ 50 mA
    Output 2
    Relay / SSR DriveTo be Specified (Factory Set)
    Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
    SSR Drive12 VDC @ 50 mA
    Functional Specification
    Control ActionT.P or ON/OFF
    Control Parameter
    HysteresisJ, K, R, S, RTD : 1 to 99 C
    RTD.1: 0.1 to 99.9 C
    Delay0 to 500 Sec
    Proportional Band0.5 to 99.9C
    Cycle Time0.5 to 100.0 Sec
    Aux. ControlAbsolute / Deviation
    Output 2 Function
    AlarmLow /High /Band /Deviation
    Alarm Hysteresis, K, R, S, RTD : 1 to 99 C
    RTD.1 : 0.1 to 99.9 C
    General Specification
    Supply Voltage
    90 - 270 VAC/DC
    24 VAC/DC (OPTIONAL)
    Temperature
    Operating0 - 50C
    Storage-20 to 75C


    High Accuracy Fast Alcohol Detection

    Using an electrochemical fuel cell sensor, the AI-5X42 delivers accurate alcohol readings within seconds. The device warms up in 15 seconds and provides results in as little as 5 seconds, making it perfect for high-throughput screening environments like checkpoints and professional settings.


    Seamless Data Management and Connectivity

    The breathalyzer includes storage capacity for 5,000 results, and supports easy data transfer to a PC via USB or RS232. The optional GPS feature and compatible PC software make result management comprehensive and traceable, fitting well into professional reporting workflows.


    Robust Design for All Environments

    Operable in humidity levels of up to 95% RH and temperature ranges between -10C to +50C, the AI-5X42 is built for demanding conditions. Its portable size, rechargeable battery, and included carrying case ensure it remains convenient and reliable wherever you need it.

    FAQs of AI-5X42 .:


    Q: How do I operate the AI-5X42 alcohol tester for accurate results?

    A: To use the AI-5X42, power it on and allow a 15-second warm-up. Attach a disposable mouthpiece, then instruct the subject to blow steadily into the device. Analysis completes in about 5 seconds, with results displayed on the 2.4-inch TFT color screen.

    Q: What is the recommended calibration interval and what does it entail?

    A: It is recommended to calibrate the AI-5X42 every 6 months. Calibration involves using certified alcohol standards to ensure ongoing measurement accuracy. Professional calibration services or qualified technicians should perform this process.

    Q: When should the devices rechargeable battery be recharged, and how long does it typically last on standby?

    A: Recharge the built-in Li-ion 3.7V, 2000mAh battery using the provided USB cable when battery levels are low. The device offers more than 12 hours of standby time per charge, ensuring continuous operation across multiple testing sessions.

    Q: Where can I access and manage stored test results from the device?

    A: Stored results (up to 5,000 entries) can be accessed directly on the device or transferred to a computer using USB or RS232. Compatible PC software supports data analysis, archival, and reporting for further management.

    Q: What kind of environmental conditions can the AI-5X42 operate in?

    A: This device functions reliably within a temperature range of -10C to +50C and up to 95% relative humidity, making it suitable for diverse climate conditions encountered in field and workplace applications.

    Q: How does the built-in alarm system enhance user safety?

    A: The AI-5X42 features both audio and visual alerts that trigger when alcohol levels exceed preset thresholds, ensuring prompt awareness and action when safety limits are breached.

    Q: What are the main benefits of choosing the AI-5X42 breathalyzer?

    A: The AI-5X42 offers fast, reliable, and highly accurate breath alcohol measurements, large data storage, compatibility with professional software, and robust operation in challenging environments. It is ideal for exporters, manufacturers, and suppliers seeking dependable alcohol testing solutions in India.

    DIGITAL TEMPERATURE CONTROLLES

    • Accuracy 1% of full scale
    • Alarm High/Low temperature setpoint adjustable
    • Battery Not required (mains powered)
    • Display Type Other, Dual 4-digit 7-segment LED display
    • Includes Other, Main controller unit, instruction manual
    • Interface Other, Standard panel mount, front keys for parameter setting
    • Measuring Range -40C to 1100C (sensor dependent)
    • Memory Non-volatile memory for parameter retention
    • Net Weight 200g (approx.)
    • Power Supply 90-250V AC, 50/60Hz
    • Resolution 0.1C (above 100C: 1C)
    • Size 4848 mm (standard panel size)
    • Standby Time Continuous operation when powered
    • Temperature Range -40C to 1100C
    • Theory Other , PID/ON-OFF control method
    • Type Other, Digital Temperature Controller
    • Unit of Measure ,

    AI-5X82

    Features


    • Low cost, Effective, Easy to use PID Temperature Controller
    • 4 Digits Dual Row Display (4-Digits for PV & 4-Digits for SV)
    • Selectable sensor input (T/C : J, K,R,S & RTD) from keyboard
    • Programmable Lower & Upper set point limits
    • Programmable control action ON-OFF/T.P control
    • Programmable hysteresis in ON-OFF mode
    • Programmable time delay to activate output in ON-OFF mode
    • Selectable heat/cool logic in ON-OFF control mode
    • Four different alarm modes (Low/High/Band/Deviation)
    • Alarm latch / Alarm inhibit function
    • Programmable soak timer
    • Settable soak time delay
    • Program lock function (To prevent unauthorized tampering)
    • Universal supply voltage ranges from 90 To 270 VAC
    • Available in 5 Standard DIN sizes


    Specification

    SeriesAI-5X82
    Display
    Type7 Segment LED
    No. of Digit4 Digit Single Row
    LED IndicationOutput Status, Soak Time
    Display heightTable No.1
    Input Specification
    Measurement
    InputThermocouple J, K, R, S;
    RTD: pt-100
    Indication Accuracy0.3% FS
    ResolutionJ, K, R, S : 1C
    RTD : 1C / 0.1 C
    Output Specification
    Set Points
    No. of Set Points2
    SP Range LimitJ : 0 to 760 C K : -99 to 1200 C
    R : 0 to 1700 C
    S : 0 to 1700 C
    RTD : -100 to 450 C
    RTD.1 : -99.9 to 450.0 C
    Output 1
    Relay / SSR DriveTo be Specified (Factory Set)
    Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
    SSR Drive12 VDC @ 50 mA
    Output 2
    Relay / SSR DriveTo be Specified (Factory Set)
    Relay Contact Rating5 A @ 250 VAC/30 VDC resistive
    SSR Drive12 VDC @ 50 mA
    Functional Specification
    Control ActionT.P or ON/OFF
    Control Parameter
    HysteresisJ, K, R, S, RTD : 1 to 99 C
    RTD.1: 0.1 to 99.9 C
    Delay0 to 500 Sec
    Proportional Band0.5 to 99.9C
    Cycle Time0.5 to 100.0 Sec
    Aux. ControlAbsolute / Deviation
    Output 2 Function
    AlarmLow /High /Band /Deviation
    Alarm Hysteresis, K, R, S, RTD : 1 to 99 C
    RTD.1 : 0.1 to 99.9 C
    Soak Timer1-9999 mins.
    General Specification
    Supply Voltage
    90 - 270 VAC/DC
    24 VAC/DC (OPTIONAL)
    Temperature
    Operating0 - 50C
    Storage-20 to 75C
    Humidity (Non-condensing)95 % RH
    Dimensions & WeightTable no : 2


    Versatile Sensor Compatibility

    The controller supports both Thermocouple (K, J, T) and RTD (Pt100) inputs, making it ideal for diverse temperature measurement applications. You can easily select the appropriate sensor for your process, ensuring accurate readings across a broad measuring range from -40C to 1100C, suitable for various industrial setups.


    Flexible and Precise Control Modes

    Choose between advanced PID auto-tuning and straightforward ON/OFF control to optimize your process needs. The PID mode offers automatic adjustment for highly stable temperature management, while the ON/OFF mode simplifies control for less critical applications. This adaptability helps maximize process efficiency and product quality.


    Robust Housing with Enhanced Protection

    Constructed from ABS flame-retardant material, the device features a panel mounting design with locking clips for secure installation. The front panel carries an IP54 rating, protecting against dust and splashes, making it suitable for demanding industrial environments. Its compact 4848110 mm dimensions facilitate easy integration into standard panels.

    FAQs of DIGITAL TEMPERATURE CONTROLLES:


    Q: How does the Digital Temperature Controller maintain stable temperature readings?

    A: Stability is achieved through PID auto-tuning control, which dynamically adjusts output to maintain precise temperature setpoints. The controller samples data three times per second and provides ON/OFF selectable control for simpler applications, ensuring consistent temperature regulation.

    Q: What sensor types are compatible with this controller?

    A: The unit supports Thermocouple types K, J, T, and RTD (Pt100) sensors, allowing users to select based on measurement range and environment requirements. This flexibility ensures compatibility with a wide array of industrial processes.

    Q: Where is the recommended location for installing the temperature controller?

    A: It is designed for panel mounting using locking clips for stability. Ideally, install it in a clean, accessible area with ambient temperature between 0C and 50C. The IP54-rated front panel protects against dust and moisture, making it suitable for factory and laboratory settings.

    Q: What is the process for setting parameters and control modes?

    A: Users can easily set parameters and select control modes using the front keys located on the devices standard panel mount interface. The controller retains all settings in non-volatile memory, ensuring reliable operation even after power interruptions.

    Q: What are the advantages of using a relay or SSR driver output?

    A: Relay (SPST) output enables straightforward switching for heating/cooling loads, while the SSR driver output offers silent, rapid switching for solid-state relays. This enhances reliability and supports applications with frequent switching demands.

    Q: When is the alarm feature beneficial and how is it used?

    A: The alarm function, with adjustable high/low setpoints, is valuable for processes requiring strict temperature limits. It alerts operators when temperatures deviate from safe ranges, helping prevent equipment damage or product spoilage.

    X


    Back to top