ELTEC CABLES AND INSTRUMENTS
None

Call us:

trusted seller
TIMER KEYBOARD BASED KTM-XX3 Series

TIMER KEYBOARD BASED KTM-XX3 Series

Product Details:

X

Product Description

KTM-XX3 Series


Features

  • Low cost, Effective, Easy to use Keyboard based Digital timer
  • Programmable timer start modes to suit various applications
  • Programmable Up/Down counting
  • Programmable Front Reset
  • Programmable Output 2 functions : Auxiliary contact/End of cycle/Instant contact
  • Multiple Time Range: From 0.01 Sec. to 999 Hrs.
  • Time Setting via keyboard
  • Configuration at power on (To prevent unauthorized tampering)
  • Available in 5 Standard DIN sizes
  • 3-Digit display
  • Programmable ON Delay/Interval/Cyclic/Forward-Reverse mode
  • Programmable Auto Reset/Latch Output
  • Programmable Memory Backup
  • High Accuracy: 0.05% of Full scale (Repeat Accuracy: 0.01%)
  • Time base selection via keyboard
  • Independent time base for both cycles in Cyclic mode
  • Universal supply voltage ranges from 90 To 270 VAC
  • Specification

    KTM-3D
    SeriesEconomical keyboard Counter
    DisplayType7 segment LED
    No. of Digits4 Digits, Single Row
    LED IndicationOutput Status ; Batch/AR Time
    DimensionsTable no : 1
    Input Specification
    Start InputPower On, Pulse (Edge Trigger),Front Start (Programmable)
    Reset InputFront Key & Rear Terminal (Potential free)
    AccuracySetting : 0.05% of Full scale Repeat : 0.01%
    Output Specification
    No. Of Outputs2
    Output 1Relay / SSRFactory settings
    Relay Contact Rating5 A @ 250V AC/30V DC resistive
    SSR12 VDC @ 50mA
    Output 2Relay / SSRFactory settings
    Relay Contact Rating5 A @ 250V AC/30V DC resistive
    SSR12 VDC @ 50mA
    Configuration Parameters
    Delay ModesOn Delay/Interval/Cyclic ON time first/Cyclic OFF time first/Cyclic Hold-Forward-Hold-Reverse-Hold
    Time Range9.99 Sec ; 99.9 Sec ; 999 Sec
    9.59 Min : Sec
    99.9 Min ; 999 Min
    9.59 Hrs : Min
    99.9 Hrs ; 999 Hrs
    Timer Start ModesPower On Start
    Pulse Start (Edge Triggered)
    Front Start Pulse Start (Edge +Level )
    Programmable No. of CycleApplicable in On delay/Off delay CY1 & CY2 Mode Only
    Timing Accuracy0.05 % Full scale
    Time Base SelectionThrough Keyboard
    Front Panel ResetEnable/Disable
    Memory BackupEnable/Disable
    Output 2 ConfigurableAuxiliary Contact
    Batch Mode
    General Specification
    Supply Voltage90 - 270 VAC/DC
    24 VAC/DC (OPTIONAL)
    TemperatureOperating0 - 50°C
    Storage-20° to 75°C
    Humidity (Non-condensing)95 % RH
    Weight
    Enter Buying Requirement Details
    Email Id
    Mobile number


    Back to top