J TYPE thermocouple wire is commonly used to link the thermocouple to control instrumentation. It may also be used to build the sensing point and can be used as a J TYPE THERMOCOUPLE SENSOR or used in manufacturing THERMOCOUPLE ASSEMBLIES or can used to connect to DATA LOGGERS via THERMOCOUPOLE CONNECTORS.
PTFE Insulation becomes an excellent solution where chemical fumes & other liquids make all type of Insulation vulnerable as it is chemically inert to most of industrial chemicals. It has outstanding mechanical & electrical properties and temperature range from -65 C to 260 C
TYPE OF TC
Metal Alloy + ve leg
Metal Alloy - ve leg
Measuring Temp. Range
J
Iron, Fe
Constantan - Cu Ni
-210 C - 760 C
Grade
Sprak Testing
Die Electric Testing
ET (250 V)
2500 V ACrms
1500 V ACrms
Conductor
Solid or Multi stranded Original THERMOCOUPLE GRADE
Core Insulation
FUSED PTFE Insulation
Core Laying
Parallel or twisted
No. of Pair
1, 2 or more
Outer Sheath
FUSED PTFE / VARNISHED FIBER GLASS as reqd.
Outer Jacket
Outside SS Metal Braided
Color Coding
As per IEC, ANSI, BS, DIN, NFC, JIS etc. Refer table
Packing
100 Mtrs. coil or 500 Mtrs. spool
J Type Thermocouple Wire with PTFE Insulation features
High dielectric values resulting in excellent resulting in space & weight saving Wide operating temperature from -65 C to 260 C Inert to most chemicals & fluids even at elevated temperature & pressure. Unaffected by oils, lubricants & hydraulic fluids Non flammable, non toxic, resistant to solder iron damage. Suitable for high frequency operation. Immune to agene, fungus & water absorption. Resistance to UV resistance & stress creaking. High strain & abrasion resistance.