About T TYPE FIBER GLASS THERMOCOUPLE WIRE
FIBER GLASS
T TYPE thermocouple grade wire is commonly used to build the thermocouple probe. It may also be used to build the sensing point and can be used as a T TYPE THERMOCOUPLE SENSOR or used in manufacturing THERMOCOUPLE ASSEMBLIES or can used to connect to DATA LOGGERS via THERMOCOUPOLE CONNECTORS.
FIBER GLASS INSULATION is ideal for general application requiring moderate abrasion, moisture resistance & high temperature resistance.
| Conductor | Solid or Multi stranded Original THERMOCOUPLE GRADE |
| Core Insulation | FIBER GLASS VARNISHED |
| Core Laying | Parallel or twisted |
| No. of Pair | 1, 2 or more possible |
| Outer Sheath | FIBER GLASS VARNISHED |
| Outer Jacket | Outside SS Metal Braided |
| Color Coding | As per IEC, ANSI, BS, DIN, NFC, JIS etc. Refer table |
| Packing | 100 Mtrs. coil / 500 Mtrs. spool / 1000 Mtrs. drum |
Thermocouple Wire with Fiberglass Insulation Features:
Good thermal durability and tensile strength.
Service temperature up to 180 C with varnish but up to 400 C without varnish.
Good dielectric and electrical characteristics.
Braided fiberglass insulation for abrasion resistance.
Braided fiberglass jacket for additional flexibility and abrasion resistance
| PART NO. | Wire Size AWG | Type of Wire | INSULATION | Max. Temp. | Overall Dimension |
|---|
| CORE | OVERALL |
|---|
| T TYPE WIRE with INDIVIDUAL CORE & OVERALL FIBER GLASS INSULATION |
| Tx-16FF | 16 | Solid | FIBER GLASS BRAID | FIBER GLASS BRAID | 400 C | |
| Tx-18FF | 18 | Solid | 400 C | |
| Tx-20FF | 20 | Solid | 400 C | |
| Tx-22FF | 22 | Solid | 400 C | |
| Tx-24FF | 24 | Solid | 400 C | |
| Tx-26FF | 26 | Solid | 400 C | |
| Tx-28FF | 28 | Solid | 400 C | |
| Tx-19*32FF | 32 | 19x32 | 400 C | |
| Tx-7*32 FF | 32 | 7 x 32 | 400 C | |
| T TYPE WIRE with INDIVIDUAL CORE & OVERALL FIBER GLASS INSULATION & STAINLESS STEEL BRAID |
| Tx-16FFS | 16 | Solid | FIBER GLASS BRAID | FIBER GLASS BRAID WITH SS METAL BRAID | 400 C | |
| Tx-18FFS | 18 | Solid | 400 C | |
| Tx-20FFS | 20 | Solid | 400 C | |
| Tx-22FFS | 22 | Solid | 400 C | |
| Tx-24FFS | 24 | Solid | 400 C | |
| Tx-26FFS | 26 | Solid | 400 C | |
| Tx-28FFS | 28 | Solid | 400 C | |
| Tx-20FFS | 20 | Solid | 400 C | |
| Tx-19*32 FF | 32 | 14 x 32 | 400 C | |
| Tx-7*32 FF | 32 | 7 x 32 | 400 C | |
Additional T TYPE WIRE with other wire sizes in solid & stranded combinations are available.
Additional T TYPE WIRE with other different Insulation & overall combination are also available.
All above T TYPE WIRE are available in DUPLEX and also in twisted form. Duplex T Type wire is suffix with KxD.
Superior Temperature Measurement for Demanding EnvironmentsDesigned for industrial and instrumentation use, the T Type Fiber Glass Thermocouple Wire provides accurate temperature monitoring across a wide rangefrom sub-zero conditions up to 400C. Its robust fiber glass insulation guarantees reliability in hostile, humid, or corrosive environments. With excellent flexibility, the wire easily fits into complex installations without compromising performance.
Customizable to Meet Your Specific NeedsOffering versatility, this wire is available in various gauges, core types (solid or stranded), and color codes as per Type T standards. Choose between unshielded or shielded variants for added protection, and select the most suitable length for your application. Whether you require open ends, terminals, or connectors, the configuration will match your instrumentation needs.
FAQs of T TYPE FIBER GLASS THERMOCOUPLE WIRE:
Q: How does the high-temperature fiber glass insulation benefit thermocouple wire performance?
A: The high-temperature fiber glass insulation provides outstanding resistance to heat, flame, and ambient humidity. This ensures stable operation from -60C to +400C, making the wire ideal for harsh industrial environments and process control applications.
Q: What are the typical application scenarios for T Type Fiber Glass Thermocouple Wire?
A: This wire is primarily used in temperature sensors, process control systems, and industrial instrumentation where accurate temperature monitoring is essential. It is suitable for installation in locations with high temperatures, humidity, and exposure risk.
Q: When should I choose shielded T Type Thermocouple Wire over the standard unshielded option?
A: Shielded wire is recommended when electromagnetic interference is a concern in your operating environment. It helps reduce signal noise, ensuring accurate temperature readings in sensitive applications.
Q: Where is this thermocouple wire commonly installed?
A: It is commonly found in factories, laboratories, and industrial plantswherever precise and reliable temperature measurement is required. Its high flexibility allows routing in tight or complex spaces.
Q: How is the wire packaged and what length options are available?
A: The wire is supplied in coils, spools, or cut to length as per customer requirements. Both standard rolls and customized lengths can be ordered to fit specific instrumentation needs.
Q: What is the process for connecting this wire to temperature measurement devices?
A: The wire features open ends, terminals, or thermocouple connectors based on your request. Installation involves attaching these ends directly to your temperature measurement device following standard thermocouple wiring procedures.
Q: What are the main benefits of using T Type Fiber Glass Thermocouple Wire in industrial settings?
A: Key benefits include accurate and reliable temperature measurement, high resistance to flame and humidity, robust mechanical flexibility, custom length options, and good overall durability in corrosive or demanding environments.