T TYPE FIBER GLASS THERMOCOUPLE WIRE
T TYPE FIBER GLASS THERMOCOUPLE WIRE

T TYPE FIBER GLASS THERMOCOUPLE WIRE

T TYPE FIBER GLASS THERMOCOUPLE WIRE Specification

  • Conductor Type
  • Solid or Stranded Core (based on requirement)
  • No Of Core
  • 2 (Duplex Wire)
  • Temperature
  • -60C to +400C (Continuous)
  • Cable Length
  • Custom lengths or standard rolls
  • Connector Type
  • Open wire, terminals, or thermocouple connectors
  • Product Type
  • T Type Thermocouple Wire
  • Material
  • Fiber Glass
  • Function
  • Temperature Measurement
  • Usage
  • Thermocouple Applications
  • Voltage Surge
  • Withstands standard industrial surges
  • Rated Voltage
  • 300V
  • Rated Current
  • Depends on configuration, typically 2A max
  • Cable Capacity
  • Standard for thermocouple instrumentation
  • Insulation Material
  • Fiber Glass
  • Conductor Material
  • Copper-Constantan (Type T Alloy)
  • Length
  • As per requirement (customized lengths available)
  • Size
  • Standard or custom gauge (e.g., 24 AWG)
  • Color
  • Typically Blue/Red (as per Type T coding)
  • Diameter
  • Approx. 1.2mm to 2.0mm (based on gauge and insulation)
  • Application
  • Temperature sensors, Process Control, Industrial Instruments
 
 

About T TYPE FIBER GLASS THERMOCOUPLE WIRE


FIBER GLASS

T TYPE thermocouple grade wire is commonly used to build the thermocouple probe. It may also be used to build the sensing point and can be used as a T TYPE THERMOCOUPLE SENSOR or used in manufacturing THERMOCOUPLE ASSEMBLIES or can used to connect to DATA LOGGERS via THERMOCOUPOLE CONNECTORS.
FIBER GLASS INSULATION is ideal for general application requiring moderate abrasion, moisture resistance & high temperature resistance.



ConductorSolid or Multi stranded Original THERMOCOUPLE GRADE
Core InsulationFIBER GLASS VARNISHED
Core LayingParallel or twisted
No. of Pair1, 2 or more possible
Outer SheathFIBER GLASS VARNISHED
Outer JacketOutside SS Metal Braided
Color CodingAs per IEC, ANSI, BS, DIN, NFC, JIS etc. Refer table
Packing100 Mtrs. coil / 500 Mtrs. spool / 1000 Mtrs. drum


Thermocouple Wire with Fiberglass Insulation Features:

Good thermal durability and tensile strength.
Service temperature up to 180 C with varnish but up to 400 C without varnish.
Good dielectric and electrical characteristics.
Braided fiberglass insulation for abrasion resistance.
Braided fiberglass jacket for additional flexibility and abrasion resistance


PART NO.Wire Size AWGType of WireINSULATIONMax. Temp.Overall Dimension
COREOVERALL
T TYPE WIRE with INDIVIDUAL CORE & OVERALL FIBER GLASS INSULATION
Tx-16FF16SolidFIBER GLASS BRAIDFIBER GLASS BRAID400 C
Tx-18FF18Solid400 C
Tx-20FF20Solid400 C
Tx-22FF22Solid400 C
Tx-24FF24Solid400 C
Tx-26FF26Solid400 C
Tx-28FF28Solid400 C
Tx-19*32FF3219x32400 C
Tx-7*32 FF327 x 32400 C
T TYPE WIRE with INDIVIDUAL CORE & OVERALL FIBER GLASS INSULATION & STAINLESS STEEL BRAID
Tx-16FFS16SolidFIBER GLASS BRAIDFIBER GLASS BRAID
WITH SS METAL
BRAID
400 C
Tx-18FFS18Solid400 C
Tx-20FFS20Solid400 C
Tx-22FFS22Solid400 C
Tx-24FFS24Solid400 C
Tx-26FFS26Solid400 C
Tx-28FFS28Solid400 C
Tx-20FFS20Solid400 C
Tx-19*32 FF3214 x 32400 C
Tx-7*32 FF327 x 32400 C
Additional T TYPE WIRE with other wire sizes in solid & stranded combinations are available.
Additional T TYPE WIRE with other different Insulation & overall combination are also available.
All above T TYPE WIRE are available in DUPLEX and also in twisted form. Duplex T Type wire is suffix with KxD.


Superior Temperature Measurement for Demanding Environments

Designed for industrial and instrumentation use, the T Type Fiber Glass Thermocouple Wire provides accurate temperature monitoring across a wide rangefrom sub-zero conditions up to 400C. Its robust fiber glass insulation guarantees reliability in hostile, humid, or corrosive environments. With excellent flexibility, the wire easily fits into complex installations without compromising performance.


Customizable to Meet Your Specific Needs

Offering versatility, this wire is available in various gauges, core types (solid or stranded), and color codes as per Type T standards. Choose between unshielded or shielded variants for added protection, and select the most suitable length for your application. Whether you require open ends, terminals, or connectors, the configuration will match your instrumentation needs.

FAQs of T TYPE FIBER GLASS THERMOCOUPLE WIRE:


Q: How does the high-temperature fiber glass insulation benefit thermocouple wire performance?

A: The high-temperature fiber glass insulation provides outstanding resistance to heat, flame, and ambient humidity. This ensures stable operation from -60C to +400C, making the wire ideal for harsh industrial environments and process control applications.

Q: What are the typical application scenarios for T Type Fiber Glass Thermocouple Wire?

A: This wire is primarily used in temperature sensors, process control systems, and industrial instrumentation where accurate temperature monitoring is essential. It is suitable for installation in locations with high temperatures, humidity, and exposure risk.

Q: When should I choose shielded T Type Thermocouple Wire over the standard unshielded option?

A: Shielded wire is recommended when electromagnetic interference is a concern in your operating environment. It helps reduce signal noise, ensuring accurate temperature readings in sensitive applications.

Q: Where is this thermocouple wire commonly installed?

A: It is commonly found in factories, laboratories, and industrial plantswherever precise and reliable temperature measurement is required. Its high flexibility allows routing in tight or complex spaces.

Q: How is the wire packaged and what length options are available?

A: The wire is supplied in coils, spools, or cut to length as per customer requirements. Both standard rolls and customized lengths can be ordered to fit specific instrumentation needs.

Q: What is the process for connecting this wire to temperature measurement devices?

A: The wire features open ends, terminals, or thermocouple connectors based on your request. Installation involves attaching these ends directly to your temperature measurement device following standard thermocouple wiring procedures.

Q: What are the main benefits of using T Type Fiber Glass Thermocouple Wire in industrial settings?

A: Key benefits include accurate and reliable temperature measurement, high resistance to flame and humidity, robust mechanical flexibility, custom length options, and good overall durability in corrosive or demanding environments.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Thermocouple Cables Category

Silicon Rubber Thermocouple Wire

Silicon Rubber Thermocouple Wire

Usage : Industrial Heat Sensing, HighTemperature Applications

Product Type : Silicon Rubber Thermocouple Wire

Material : Silicon Rubber

Color : Red, Yellow, Blue, or as per thermocouple standard

ELTEC PTFE Insulated Thermocouple Cable

ELTEC PTFE Insulated Thermocouple Cable

Price 50 INR / Meter

Minimum Order Quantity : 1 Meter

Usage : Industrial

Product Type : ELTEC PTFE Insulated Thermocouple Cable

Material : ELTEC

Color : Multicolour

ELTEC PTFE Insulated Shielded Thermocouple Wire

ELTEC PTFE Insulated Shielded Thermocouple Wire

Price 55 INR / Meter

Minimum Order Quantity : 100

Usage : Industrial

Product Type : ELTEC PTFE Insulated Shielded Thermocouple Wire

Material : PTFE

K TYPE SILICON RUBBER THERMOCOUPLE WIRE

K TYPE SILICON RUBBER THERMOCOUPLE WIRE

Minimum Order Quantity : 100

Usage : Industrial

Product Type : SILICON RUBBER THERMOCOUPLE WIRE

Material : SILICON

Color : Orange Green



Back to top